Bard Power-Trialysis Скачать руководство пользователя страница 9

REFERENCES

1  Aitken, Delmar R., and John P. Minton. “The ‘Pinch-Off Sign’ :  A Warning of Impending Problems with Permanent Subclavian

 Catheters.” 

The American Journal of Surgery

, 148.ve (1984): 633-663.

2  Ingle, Rebecca J., and Corinne S. Nace. “Venous Access Devices: Catheter Pinch-off and Fracture.” 

C. R. Bard,

 1993.

3  Sulek, Cheri A., Mark L. Blas, and Emilio B. Lobato. “A Randomized Study of Left versus Right Internal Jugular Vein Cannulation  

in Adults.” 

Journal of Clinical Anesthesia,

 12.2 (2000): 142-145.

4  National Kidney Foundation K/DOQI Guidelines, (2006).

5  O’ Grady, Naomi P., et al. Department of Health and Human Services USA. “Guidelines for the Prevention of Intravascular  

Catheter-Related Infections.” 

Morbidity and Mortality Weekly Report,

 51. RR-10 (2002): 1-32.

Other references available upon request.

Bard Access Systems, Inc. warrants to the original purchaser that this product will be free from defects in material and workmanship for 
a period of one (1) year from the date of purchase. If this product proves to be so defective, purchaser may return same to Bard Access 

Systems, Inc. for repair or replacement, at Bard Access Systems, Inc.’s option. All returns must be authorized in advance in accordance 
with Bard Access Systems, Inc.’s Returned Goods Policy found in its then current Price List. The liability of Bard Access Systems, Inc. under 
this limited product warranty does not extend to any abuse or misuse of this product or its repair by anyone other than an authorized Bard 

Access Systems, Inc. representative.

THIS LIMITED PRODUCT WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION ANY 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE). THE LIABILITY AND REMEDY STATED IN THIS LIMITED PRODUCT 
WARRANTY WILL BE THE SOLE LIABILITY OF BARD ACCESS SYSTEMS, INC. AND REMEDY AVAILABLE TO PURCHASER FOR THIS PRODUCT, 
WHETHER IN CONTRACT, TORT (INCLUDING NEGLIGENCE) OR OTHERWISE, AND BARD ACCESS SYSTEMS, INC. WILL NOT BE LIABLE TO 
PURCHASERS FOR ANY INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF ITS HANDLING OR USE.

Some states/countries do not allow an exclusion of implied warranties, incidental or consequential damages. You may be entitled to addi-

tional remedies under the laws of your state/country. An issued or revision date for these instructions is included for the user’s information. 

In the event two years have elapsed between this date and product use, the user should contact Bard Access Systems, Inc. to see if addi-

tional product information is available.  

Revised date:  February 2015

Bard, Alphacurve, Dualator and Power-Trialysis are trademarks and/or registered trademarks of C. R. Bard, Inc. All other trademarks are the 

property of their respective owners.   

2015 C. R. Bard, Inc. All rights reserved. 

Содержание Power-Trialysis

Страница 1: ...or Use SHORT TERM DIALYSIS CATHETERS SHORT TERM DIALYSIS CATHETERS Bard Access Systems Inc 605 North 5600 West Salt Lake City UT 84116 USA 1 801 522 5000 Clinical Information Hotline 1 800 443 3385 Or...

Страница 2: ...blood return and vigorously flush the catheter with the full 10 mL of sterile normal saline WARNING To prevent systemic heparanization of the patient the heparin solution must be aspirated out of the...

Страница 3: ...e grades of Pinch off that should be recognized with appropriate chest x ray as follows 2 The catheter must not be left in the femoral vein longer than three days It is recommended that jugular and su...

Страница 4: ...r Injectable for power injection of contrast media Power injection machine pressure limiting feature may not prevent over pressurization of an occluded catheter which may lead to cath eter failure Exc...

Страница 5: ...to expose the side of the groin to be accessed 2 Prepare the access site using standard surgical technique and drape the prepped area with sterile towels If hair removal is necessary use clippers or d...

Страница 6: ...e 2 Secure the wing onto the catheter by tying sutures around the wing using the suture grooves 3 Secure the removable wing in place by suturing through the holes or by using adhesive wound closures W...

Страница 7: ...lution injection is necessary for 48 72 hours provided the catheter has not been aspirated or flushed 3 Maintain patency of distal purple lumen per institution protocol for central lines 4 Clean cathe...

Страница 8: ...the average static burst pressure to the catheter pressure during power injection at 5 mL sec flow rate assuming patency of the catheter has been verifed Dialysis Lumen Flow Information Flow Rate vs...

Страница 9: ...ity of Bard Access Systems Inc under this limited product warranty does not extend to any abuse or misuse of this product or its repair by anyone other than an authorized Bard Access Systems Inc repre...