Depending on the specific equipment involved, the surface that can accumulate debris can be on the
opposite side that is exposed to view when standing in front of the machine.  Closely review the machine
when operating to see which direction or path that the airflow moves through the machine, and if the air
inlet side of the coil is hidden, try to observe the back (hidden) side by looking into the side grilles, using
flashlight if necessary.

While the user of the equipment needs to be aware of the potential of clogging of the outdoor coil sur-
face, actual cleaning of the outdoor coil should not be attempted under most circumstances.  If the user
should attempt this procedure on their own, never do so without first having the installing dealer or
Service Company instruct you in the proper procedure and technique.

 WARNING:  Do not open or enter the equipment without first turning off the electrical service
 disconnect.  Failure to do so can result in personal injury due to moving parts and/or electric
 shock hazard resulting in death.

Other conditions that can cause reduction of airflow across the outdoor coil are flowers, shrubbery or
other growth too near the outdoor coil air inlet and outlet openings.  These living things, especially as
they mature and grow, will be just as effective in blocking the airflow and create the same problems as
will stacking things against the equipment.  These conditions can be easily managed and controlled by
the user, as they do not require actually entering into the equipment enclosure, which should only be
done by qualified service technicians.

  

ROUTINE EQUIPMENT OUTDOOR MAINTENANCE

1.

Avoid having any lawn sprinkler spray directly on the equipment, especially if from a brackish
water source.

2.

In coastal areas locate equipment the furthest distance away from the coastline as feasible.

3.

Frequent cleaning and waxing of the cabinet using a good automobile polish will help extend its
original appearance.

BASIC OPERATING PRINCIPLES

  AIR CONDITIONERS

COOLING MODE

The cooling mode operates similar to a refrigerator, removing heat from inside the conditioned space
and rejects it outside of the space being controlled.  There are three main parts of the system:
1.

The evaporator (indoor) coil where cold refrigerant absorbs heat from the air, which circulates
from the conditioned space, through the machine, and is returned to the space at a lower tem-
perature and with some of the humidity (moisture) removed.  The moisture exits through a con-
densate drain system.  A motor/blower assembly  moves the indoor air through the system.

2.

The compressor, which is a sealed pump that moves the refrigerant through the system.

3.

The condenser (outdoor) coil where the heat that was absorbed from the indoor space is dis-
charged to the outdoor environment.  A motor/fan system moves the outdoor air across the
condenser coil.

A properly sized air conditioner cannot cool a structure off rapidly, and instead will pull down the tem-
perature slowly.  It also will remove a certain amount of moisture (humidity) from the circulating air
stream in

2

Содержание HAC-Series

Страница 1: ...Manual 2100 439 Page USER S GUIDE For HAC Series Split System Air Conditioners HAC Series Split System Air Conditioners Manual 2100 439 Supersedes File Tab 4 Date 09 30 03 ...

Страница 2: ...quipment Outdoor Maintenance Page 2 Basic Operating Principles Page 2 Air Conditioners Page 2 3 Automatic Control Systems Page 3 Thermostats Page 3 Insufficient Cooling or Heating Page 3 Failue to Operate Page 4 Lubrication Requirements Page 4 Periodic Maintenance Page 4 Helpful Hints and Operating Practices Page 5 i ...

Страница 3: ...repair costs decrease capacity and efficiency and shorten the service life of the equipment A common symptom of a dirty filter in the cooling mode is a freeze up of the indoor coil The air filters used may be a disposable throw away type or may be a cleanable type that can be thoroughly cleaned rinsed and reused many times It is important to make sure that the correct filter size and type for your...

Страница 4: ...ly managed and controlled by the user as they do not require actually entering into the equipment enclosure which should only be done by qualified service technicians ROUTINE EQUIPMENT OUTDOOR MAINTENANCE 1 Avoid having any lawn sprinkler spray directly on the equipment especially if from a brackish water source 2 In coastal areas locate equipment the furthest distance away from the coastline as f...

Страница 5: ... and additional equipment such as a dedicated dehumidifier may be required AUTOMATIC CONTROL SYSTEMS THERMOSTATS There are many types of thermostats available to properly control your system and these can vary in features and some functions Approved compatible thermostats are available from Bard Manufacturing Company for all applications and since these can vary in numerous features and functions ...

Страница 6: ... should be made with your Service Company 2 There is a condensate drain system for all air conditioners and this must be kept open and free to convey the condensate generated by the operation of the equipment to a suitable location typically either an internal drain or outdoor location Depending upon the specific installation the user would at least be aware of the dram mechanism and know what to ...

Страница 7: ...nd force the system to run continuously to try and catch up If the building is to be unoccupied for a lengthy period it is best to adjust the thermostat to a reasonable higher or lower depending upon the season setting rather than turning it completely off Upon return the inside conditions will not be totally out of control and recovery time to desired conditions would be much shorter 5 Keep all s...

Отзывы: