GENERAL INFORMATION

This manual is intended to be a general guide for care and operation of typical systems and covers the
most important features you should be aware of and are responsible for as the user of the equipment.

The HAC outdoor unit may be connected to an indoor blower coil unit, or to an evaporator coil used in
conjunction with a gas or oil furnace.  A separate owner’s manual should be supplied with the indoor
section.  Therefore, you should request a detailed operation sequence and explanation of any special
features from your installer and/or Service Company, and also have them instruct you as to any routine
maintenance procedures you are responsible for.

  AIR FILTERS

While air filters are not a part of the HAC-Series outdoor section, they are an integral part of the indoor
section to which the HAC unit is attached.

Keeping clean air filter(s) is the single most important responsibility of the user of the equipment.  Each
type of system must be equipped with an air filter(s) in the indoor circulating air system to clean the air,
to keep the system itself clean for peak efficiency and capacity, and to prolong the useful life of the
equipment.  DO NOT operate the system without the proper air filters.

Filters should be inspected at least monthly, and replaced or cleaned (depending on type) as needed.
The useful life of an air filter can vary widely depending upon application and use of the equipment, and
it is critical to monitor filter condition and establish an acceptable maintenance schedule.  Failure to do
so will increase operating and repair costs, decrease capacity and efficiency, and shorten the service life
of the equipment.  A common symptom of a dirty filter in the cooling mode is a freeze-up of the indoor
coil.

The air filters used may be a disposable (throw-away) type or may be a cleanable type that can be
thoroughly cleaned, rinsed and reused many times.  It is important to make sure that the correct filter
size and type for your system is always used.  If there is any question as to acceptable filter size or type,
review the Installation Instructions for the specific equipment involved, if available.  Otherwise, consult
with your installing dealer or Service Company.

Most equipment can have the filters inspected and serviced by the user with no problems.  In some
instances, because of equipment design or specific installation conditions, it may be necessary to have
this procedure done by a qualified service company.  Have your installer or service company show you
where the filter(s) are and demonstrate the service procedure or make arrangements for them to provide
this service on an as needed basis.

  OUTDOOR COIL

The outdoor coil must be kept clean and free of any airborne debris, which can accumulate over time.
Large volumes of air are circulated over the coil, and airborne debris such as lint, dust, materials shed
from trees, paper or other types of airborne material that can become airborne can collect on the enter-
ing coil surface.

The outdoor coil must dissipate heat during the cooling mode, and for a heat pump must also absorb
heat during the heating mode.  If the coil is dirty and matted with debris, the airflow across the coil will be
reduced causing poor performance, increased operating runtime and associated utility bills, and in
extreme conditions can shorten the useful life of the equipment.

1

Содержание HAC-Series

Страница 1: ...Manual 2100 439 Page USER S GUIDE For HAC Series Split System Air Conditioners HAC Series Split System Air Conditioners Manual 2100 439 Supersedes File Tab 4 Date 09 30 03 ...

Страница 2: ...quipment Outdoor Maintenance Page 2 Basic Operating Principles Page 2 Air Conditioners Page 2 3 Automatic Control Systems Page 3 Thermostats Page 3 Insufficient Cooling or Heating Page 3 Failue to Operate Page 4 Lubrication Requirements Page 4 Periodic Maintenance Page 4 Helpful Hints and Operating Practices Page 5 i ...

Страница 3: ...repair costs decrease capacity and efficiency and shorten the service life of the equipment A common symptom of a dirty filter in the cooling mode is a freeze up of the indoor coil The air filters used may be a disposable throw away type or may be a cleanable type that can be thoroughly cleaned rinsed and reused many times It is important to make sure that the correct filter size and type for your...

Страница 4: ...ly managed and controlled by the user as they do not require actually entering into the equipment enclosure which should only be done by qualified service technicians ROUTINE EQUIPMENT OUTDOOR MAINTENANCE 1 Avoid having any lawn sprinkler spray directly on the equipment especially if from a brackish water source 2 In coastal areas locate equipment the furthest distance away from the coastline as f...

Страница 5: ... and additional equipment such as a dedicated dehumidifier may be required AUTOMATIC CONTROL SYSTEMS THERMOSTATS There are many types of thermostats available to properly control your system and these can vary in features and some functions Approved compatible thermostats are available from Bard Manufacturing Company for all applications and since these can vary in numerous features and functions ...

Страница 6: ... should be made with your Service Company 2 There is a condensate drain system for all air conditioners and this must be kept open and free to convey the condensate generated by the operation of the equipment to a suitable location typically either an internal drain or outdoor location Depending upon the specific installation the user would at least be aware of the dram mechanism and know what to ...

Страница 7: ...nd force the system to run continuously to try and catch up If the building is to be unoccupied for a lengthy period it is best to adjust the thermostat to a reasonable higher or lower depending upon the season setting rather than turning it completely off Upon return the inside conditions will not be totally out of control and recovery time to desired conditions would be much shorter 5 Keep all s...