For example, projectors that have a HD greater than 1 m and emit light into an uncontrolled area where
persons may be present should be positioned in accordance with
“
the fixed projector installation
”
parameters,
resulting in a HD that does not extend into the audience area unless the beam is at least 2.0 meter above the
floor level. In environments where unrestrained behavior is reasonably foreseeable, the minimum separation
height should be greater than or equal to 3.0 meter to prevent potential exposure, for example by an individual
sitting on another individual's shoulders, within the HD. Sufficiently large separation height may be achieved
by mounting the image projector on the ceiling or through the use of physical barriers.
RA
TH
PR
RZ
HD
SW
1
m
SW
SW
SW
HD
EXIT
SH
RA
PR
TH
RZ
SH
(B) TOP VIEW
(A) SIDE VIEW
Image 1-2
A
Side view.
B
Top view.
RA
Restricted Access location (boot area of
projector).
PR
Projector.
TH
Theater.
RZ
Restriction Zone in the theater.
SH
Separation Height.
SW
Separation Width.
Based on national requirements, no person is allowed to enter the projected beam within the zone between
the projection lens and the related hazard distance (HD). This shall be physically impossible by creating
sufficient separation height or by placing barriers. The minimum separation height takes into account the
surface upon which persons other than operator, performers or employees are permitted to stand.
On Image 1-3 a typical setup is displayed. It must be verified if these minimum requirements are met. If
required a restricted zone (RZ) in the theater must be established. This can be done by using physical barrier,
like a red rope as illustrated in Image 1-3.
The restricted area sticker can be replaced by a sticker with only the symbol.
Содержание UDM Series
Страница 1: ...ENABLING BRIGHT OUTCOMES User manual UDM...
Страница 22: ...R5911443 02 UDM 22 Safety information...
Страница 30: ...R5911443 02 UDM 30 1 Image 2 16 Mains switch 2 Unplug the power cord from the projector Getting Started...
Страница 48: ...R5911443 02 UDM 48 Input Communication...
Страница 53: ...R5911443 02 UDM 53 4 To turn the test pattern off return to the previous menu GUI Introduction...
Страница 54: ...R5911443 02 UDM 54 GUI Introduction...
Страница 60: ...R5911443 02 UDM 60 GUI Source...
Страница 112: ...R5911443 02 UDM 112 GUI Profiles...
Страница 156: ...R5911443 02 UDM 156 Specifications...
Страница 166: ...R5911443 02 UDM 166 Video timing tables...
Страница 172: ...R5911443 02 UDM 172 DMX chart...
Страница 176: ...R5911443 02 UDM 176 WiFi GSM compliance information...
Страница 182: ...R5911443 02 UDM 182 Environmental information...