background image

B. Environmental information

B.6 Contact information

Barco contact information

Registered of

fi

ce address: President Kennedypark 35, 8500 Kortrijk, Belgium

Contact address: Beneluxpark 21, 8500 Kortrijk, Belgium

Importers contact information

To

fi

nd your local importer, contact Barco directly or one of Barco’s regional of

fi

ces via the contact information given on Barco’s web

site,

www.barco.com

.

B.7 Production address

Factories

Barco NV (BELGIUM)

President Kennedypark 35, B-8500 Kortrijk

CFG Barco (Beijing) Electronics Co. Ltd.

中影巴可(北京)

子有限公司

3rd Floor, Barco Factory, No.16 Changsheng Road, Changping District, 102200, Beijing, P.R.C.

北京市昌平区中

村科技园区昌平园昌盛路

16

号巴可工厂第

3

层 邮

编码

102200

Barco Visual (Beijing) Electronics Co. Ltd.

巴可

伟视

(北京)

子有限公司

No.16 Changsheng Road, Changping District, 102200, Beijing, P.R.C

北京市昌平区中

村科技园区昌平园昌盛路

16

编码

102200

Made in information

The made in country is indicated on the product ID label on the product itself.

Production date

The month and year of production is indicated on the product ID label on the product itself.

B.8 Download Product Manual

Download Product Manual

Product manuals and documentation are available online at

www.barco.com/td

.

Registration may be required; follow the instructions given on the website.

IMPORTANT!

Read Installation Instructions before connecting equipment to the mains power supply.

68

R5906787 THOR 26/01/2018

Содержание Thor

Страница 1: ...Thor User manual R5906787 02 26 01 2018...

Страница 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 36 82 11 Fax 32 56 36 883 86 Support www barco com en support Visit us at the web www barco com Printed in Belgium...

Страница 3: ...32 In a residential environment this equipment may cause radio interfer ence Guarantee and Compensation Barco provides a guarantee relating to perfect manufacturing as part of the legally stipulated...

Страница 4: ...xclusively limited to replacement of the product or refund of purchase price GNU GPL code If you would like a copy of the GPL source code contained in this product shipped to you on CD please contact...

Страница 5: ...ts 35 5 5 ICMP DisplayPort specifications 36 5 6 ICMP SDI specifications 38 5 7 ICMP HDMI 2 0 specifications 41 5 8 ICMP HDMI 1 4 specifications 44 5 9 ICMP status LEDs 46 5 10 ICMP HDD status LEDs 47...

Страница 6: ...Table of contents 2 R5906787 THOR 26 01 2018...

Страница 7: ...the necessary time to page through this manual We believe everyone will benefit from this manual Not in the least our editors who will sleep more comfortably knowing their efforts have had their effec...

Страница 8: ...1 Welcome 4 R5906787 THOR 26 01 2018...

Страница 9: ...precisely All local installation codes should be adhered to Notice on safety This equipment is built in accordance with the requirements of the international safety standards IEC60950 1 EN60950 1 UL6...

Страница 10: ...zone Restricted access location To protect untrained persons and children the projector must be installed in a restricted access location The definition of a restricted access location is a location...

Страница 11: ...le or combustible materials near the projector Barco large screen projection products are designed and manufactured to meet the most stringent safety regulations This projector radiates heat on its ex...

Страница 12: ...ed substitu tions may result in degraded performance and reliability fire electric shock or other hazards Unauthorized substitutions may void warranty Safety check Upon completion of any service or re...

Страница 13: ...or manual Rated maximum ambient temperature ta 30 C 86 F Safety Data Sheets for Hazardous Chemicals For safe handling information on chemical products consult the Safety Data Sheet SDS SDSs are availa...

Страница 14: ...let for removal of all power from the unit WARNING HIGH LEAKAGE CURRENT EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY D connecter l...

Страница 15: ...n Installation method separation height barriers detection system or other applicable control measure shall prevent hazardous eye access to the radiation within the hazard distance For example project...

Страница 16: ...orporation of the RG3 LIPs into their shows Dealers and distributors are also required to obtain a valid laser light show variance This product shall be located in such a way that all propagating beam...

Страница 17: ...ving the diffuse surface of the rear projection screen As described in High Brightness precautions Hazard Distance HD page 11 it is mandatory to create a restricted zone within the beam areas closer t...

Страница 18: ...f modifying optics Hazard Distance 0 1 2 3 4 5 6 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 Hazard Distance HD m Throw Ratio TH...

Страница 19: ...ulated e g removed and installed in a projector it needs to be homed and returned Overview Available lenses Lens selection Lens installation Lens removal Lens shift zoom focus 3 1 Available lenses Whi...

Страница 20: ...website on www barco com and click on myBarco 2 Login on If you are not yet registered create a login and password With the created login and password it is possible to enter myBarco When your login...

Страница 21: ...ls that use the lens at one of its extreme zoom positions this should be taken into account 3 3 Lens installation If no lens is installed the lasers of the Thor series projector can not be powered The...

Страница 22: ...Lens Holder front plate An audible click should be noticed Once seated there may be no airgap between lens flange and Lens Holder front plate Caution Ensure that the lock handle remains in the locked...

Страница 23: ...der 1 Support the lens with one hand while you unlock the lens holder by sliding the lock handle reference 1 image 3 5 towards the unlocked position as illustrated 2 Gently pull the lens out of the le...

Страница 24: ...t s mechanical possible to shift outside the recommended field of view but this will result in a decline of image quality depending on the used lens and the zoom position of the used lens Furthermore...

Страница 25: ...h indicates that the button is enabled PURPLE When pushing the Shift Zoom or Focus button the backlight color is purple of the part of the button that is pushed This indicates that the requested actio...

Страница 26: ...3 Lenses Lens selection 22 R5906787 THOR 26 01 2018...

Страница 27: ...s located on the top side of the projector The projector card cage is equipped with an ICMP See illustration below Note that all information about the ICMP is gathered into one separated chapter ICMP...

Страница 28: ...dby mode the total power consumption of the projector is less than 15W All electronics are switched of including PSUs for the lasers except for Cinema Controller board and Local Keypad Only the follow...

Страница 29: ...f the CONDITIONING process After six seconds the status light will light up continuously Blinking green Ongoing CONDITIONING process Lasers are tested Continuous green Sealed compartments are fully CO...

Страница 30: ...process 5 Light button Light button reference 5 image 4 4 switches the lasers ON or OFF Pushing the Light button reference 5 image 4 4 for 3 seconds will activate or deactivate the lasers of the proj...

Страница 31: ...4 5 Functionality 1 Diagnostic LEDs The front plate of the Cinema Controller contains 4 diagnostic LEDs to display the status of the power supply reference 1 image 4 5 VTEC supply 24V supply 12V supp...

Страница 32: ...eaming As there is a need to daisy chain projectors when they are on an Ethernet network an Ethernet switch is built in the incoming network is hereby available for the internal PC and for the next de...

Страница 33: ...nd does not specify balanced control lines RS 232 is a serial control standard with a set number of conductors data rate word length and type of connector to be used The standard specifies com ponent...

Страница 34: ...4 Input Communication 30 R5906787 THOR 26 01 2018...

Страница 35: ...ration via Communicator ICMP reset Obtaining the Barco ICMP certificate Removing a HDD from the ICMP Installing a HDD into the ICMP 5 1 ICMP introduction About ICMP The ICMP is a removable electronic...

Страница 36: ...ith two HDMI 2 0 as video source Image 5 3 Front face ICMP with HDMI 2 0 Some models with DisplayPorts and one HDMI 1 4 mezzanine are still present on the field Image 5 4 Front face ICMP with DisplayP...

Страница 37: ...the failure of one disk it enters in degraded mode Content storage and playback remains available on the ICMP CAUTION The loss of one disk causes no serious consequences on the ICMP But action must b...

Страница 38: ...n drive operation cycles is 30 days During any storage period the drive non operational temperature humidity wet bulb atmospheric conditions shock vibration magnetic and electrical field specification...

Страница 39: ...tent The USB port can be used to load content DCP or keys KDM or software update NOTE These ports are recommended for fast ingest when connected to an appropriate USB 3 0 source USB Universal Serial B...

Страница 40: ...such as a computer monitor though it can also be used to transmit audio USB and other forms of data VESA designed it to replace VGA DVI and FPD Link Backward compatibility to VGA and DVI by using act...

Страница 41: ...1080 60 fps 8 bpc 10 bpc Single 3D 2048 x 1080 60 fps 8 bpc 10 bpc Single 3D 4K Horizontal SPAN 2D Full Color depth Port Display Mode 2048 x 2160 30 48 50 60 fps 8 bpc 10 bpc A B span 2D 4K Horizontal...

Страница 42: ...structure for coaxial cable and have a vested interest in extending the life of their infrastructure For tunately SMPTE recently ratified a new standard called SMPTE 424M that doubles the SDI data rat...

Страница 43: ...92M formats SMPTE Standard Source Resolution Frame Rate Display Rate Scan Type SMPTE 296M 1280 x 720 23 976 24 25 29 970 30 50 59 940 60 23 976 24 25 29 970 30 50 59 940 60 Progressive Y Cb Cr 4 2 2 1...

Страница 44: ...standard HD SDI interfaces support the Y Cb Cr colorspace both legal and full range using 4 2 2 color subsampling The Dual Link HD SDI interface can be used to carry a single 4 4 4 image having a colo...

Страница 45: ...lacement for existing analog video standards HDMI 2 0 specifications HDMI Both HDMI 2 0 inputs are fully compliant with the HDMI 1 4 1 4a 1 4b 2 0 and 2 0a revisions of the HDMI specification Full Ran...

Страница 46: ...supporting Ethernet over HDMI and such specific cables are thus not required HDMI 2 0 Supported 2D Formats Format Frame Rate Color coding Bit depth 1280x720 23 976 24 25 29 97 30 50 59 94 60 RGB YCbC...

Страница 47: ...Cr 4 4 4 YCbCr 4 2 2 8 HDMI 2 0 Supported Audio Formats Format Sample Rate Sample coding Bit depth 2 0 2 1 5 1 7 1 32 44 1 48 88 2 96 L PCM 16 20 24 HDMI 2 0 Supported Dual Twin Link Formats 2D format...

Страница 48: ...I2 input port B should contain the pixel data for Right Eye 5 8 ICMP HDMI 1 4 specifications HDMI HDMI High Definition Multimedia Interface is a compact audio video interface for transferring uncompre...

Страница 49: ...4 4 4 YCbCr 4 2 2 8 10 12 1920x1080 2048x1080 100 119 88 120 RGB YCbCr 4 4 4 YCbCr 4 2 2 8 2560x1080 23 976 24 25 29 97 30 50 59 94 60 RGB YCbCr 4 4 4 YCbCr 4 2 2 8 10 12 3840x2160 4096x2160 23 976 2...

Страница 50: ...ats Format Frame Rate Color coding Bit depth 1280x720 50 59 94 60 1920x1080 23 98 24 HDMI 1 4 Supported Audio Formats Format Sample Rate Sample coding Bit depth 2 channels 32 44 48 88 96 L PCM 16 5 1...

Страница 51: ...Green Starting Applications Green Green Applications started in normal mode Green Orange Applications started in degraded mode Blinking Red Off FIPS error Green Blinking Orange Update ongoing Orange O...

Страница 52: ...approved models of the same storage capacity See procedure Removing a HDD from the ICMP page 52 and Installing a HDD into the ICMP page 53 Ensure to insert the HDDs firmly 3 Switch on the power 4 Sta...

Страница 53: ...thority CA which issues digital certificates that authenticate the identity of or ganizations and individuals over a public system such as the Internet The certificates are also used to sign messages...

Страница 54: ...ation via Communicator About ICMP configuration Following parameters are available to configure the ICMP Global settings allows defining name of the ICMP host name network identifier and IP address wh...

Страница 55: ...ted to end After a few seconds the ICMP is requested to restart The READY LED on the front panel of the ICMP starts to blink orange In case the ICMP is installed in DP4K L series projector the lasers...

Страница 56: ...rieve the ICMP certificate directly 96 92 35 86 40 1 2 Image 5 14 Using control software to obtain the ICMP certificate 1 Use the WEB Commander to download the ICMP certificate from the ICMP main boar...

Страница 57: ...AUTION Always use a new empty spare part HDD approved by Barco to replace a malfunction HDD Do not use a HDD from another ICMP HDD set CAUTION Always make sure that all HDDs in the ICMP HDD set have t...

Страница 58: ...5 20 5 Switch on the projector In case you replace one HDD e g degraded mode the ICMP automatically starts with the RAID recovery process The red LED of the HDD which has to be rebuilt is blinking Thi...

Страница 59: ...er Keep in mind that it can take up to 10 minutes to start the lasers again after they were switched off If there are only 30 to 45 minutes between the shows it s advisable to keep the lasers on with...

Страница 60: ...the Communicator Touch Panel to switch the projector from OPERATIONAL mode to STANDBY mode As a result the lasers are deactivated if activated and the projector starts to deconditioning the sealed com...

Страница 61: ...s light is continuous green in normal condition no errors and no warnings The laser status light remains off In PRECONDITIONED mode the chillers are operational and the heat dissipation of the DMDs is...

Страница 62: ...6 Starting up 58 R5906787 THOR 26 01 2018...

Страница 63: ...jector 200 240 346 415V 50 60Hz 16A 3W N PE Y connection Power cord size range 4 sq mm to 6 sq mm 10AWG to 8AWG Circuit breaker range 25A to 40A 200 240V 3W PE 28A 50 60Hz delta connection Power cord...

Страница 64: ...t accessible USB 2 0 Video and audio watermarking Civolution NexGuard Closed captioning devices Support for SMPTE 430 10 4K 24fps is standard For 4K 60 fps 4K 3D on ICMP upgrade modules a license is r...

Страница 65: ...nce for Dual Projector TMS support Barco Alchemy is supported by the following Theater Management System TMS brands AAM Screenwriter Ymagis Melody CFG Barco Unique RosettaBridge ADDE Cin Digital Manag...

Страница 66: ...ns of the Thor Dimensions 293 5 1446 859 1135 415 293 5 298 741 6 675 1211 33 3 117 5 33 3 117 5 EXIT DRAIN EXIT DRAIN PONT OF GRAVITY 707 5 246 5 325 675 112 Image A 1 Dimensions given in millimeters...

Страница 67: ...A Specifications A 4 Technical Regulations Certificates Image A 2 EAC mark 10 Image A 3 Rohs Image A 4 CE mark Image A 5 ETL mark Image A 6 FCC label Image A 7 RCM mark R5906787 THOR 26 01 2018 63...

Страница 68: ...A Specifications 64 R5906787 THOR 26 01 2018...

Страница 69: ...which must be collected and disposed of separately from municipal waste If the battery contains more than the specified values of lead Pb mercury Hg or cadmium Cd these chemical symbols will appear be...

Страница 70: ...homogeneous materials used for this part is above the limit requirement in GB T 26572 EIP EFUP Barco EFUP 10 All Electronic Information Products EIP that are sold within Chinese Mainland must comply w...

Страница 71: ...ntage of reference value of presence 3 Note 3 The indicates that the restricted substance corresponds to the exemption B 4 Turkey RoHS compliance Turkey RoHS compliance T rkiye Cumhuriyeti AEEE Y netm...

Страница 72: ...rco Factory No 16 Changsheng Road Changping District 102200 Beijing P R C 16 3 102200 Barco Visual Beijing Electronics Co Ltd No 16 Changsheng Road Changping District 102200 Beijing P R C 16 102200 Ma...

Страница 73: ...Cinema Package DCP is a collection of digital files used to store and convey Digital Cinema DC audio image and data streams The term has been defined by Digital Cinema Initiatives DCI General practic...

Страница 74: ...ontrol standard with a set number of conductors data rate word length and type of connector to be used The standard specifies component connection standards with regard to computer interface It is als...

Страница 75: ...ard Distance 11 12 14 Modifying optics 14 Hazardous Chemicals 9 Hazards 67 HDD 33 34 52 53 About 33 Degrade mode 33 RAID broken 34 RAID recovery 33 Remove 52 53 Storage 34 Storage capacity 34 Validate...

Страница 76: ...injury 8 Projector damage 8 Safety Data Sheet SDS 9 Servicing 8 Safety Data Sheet SDS 9 Safety training 6 SDI 38 Specifications 38 Serial communication 28 Shift 19 Source input 36 3G SDI 36 DisplayPor...

Отзывы: