Alignment by switching on two beams:
LTL>alloff
LTL>0 3900 sfreq
LTL>23
2100
sfreq
LTL>0 4095 samp
LTL>23
4095
samp
Align angle and height of AOM for maximum intensity for deflected
beams.
Connect diode to multimeter and measure intensities of the modulated
beams.
Put two beams at freq 2300, amp 4095
For each beam you should obtain an intensity of at least 10 µA
AC. Also check if the intensity variation is not too high (e.g.
difference in intensity of beams less than 3 µA AC).
Содержание SilverWriter 800
Страница 6: ...Field Service Manual December 2003 Page 6 of 276 ...
Страница 8: ...Field Service Manual December 2003 Page 8 of 276 ...
Страница 18: ...Field Service Manual December 2003 Page 18 of 276 ...
Страница 20: ...Field Service Manual December 2003 Page 20 of 276 ...
Страница 24: ...Field Service Manual December 2003 Page 24 of 276 ...
Страница 75: ...Field Service Manual December 2003 Page 75 of 276 The Vacuum Pump Box Components Layout FIRST LAYOUT ...
Страница 91: ...Field Service Manual December 2003 Page 91 of 276 Electrical Devices Power panel With MM750 With MM440 ...
Страница 93: ...Field Service Manual December 2003 Page 93 of 276 Film feeder solid state panel Solid state Panels ...
Страница 95: ...Field Service Manual December 2003 Page 95 of 276 Multi FilmFeeder solid state panel ...
Страница 96: ...Field Service Manual December 2003 Page 96 of 276 ...
Страница 122: ...Field Service Manual December 2003 Page 122 of 276 ...
Страница 130: ...Field Service Manual December 2003 Page 130 of 276 ...
Страница 134: ...Field Service Manual December 2003 Page 134 of 276 ...
Страница 168: ......
Страница 172: ...Field Service Manual December 2003 Page 172 of 276 ...
Страница 174: ...Field Service Manual December 2003 Page 174 of 276 ...
Страница 187: ...Field Service Manual December 2003 Page 187 of 276 ...
Страница 216: ...Field Service Manual December 2003 Page 216 of 276 ...
Страница 220: ...Field Service Manual December 2003 Page 220 of 276 Main directory structure ...
Страница 225: ...Field Service Manual December 2003 Page 225 of 276 Adding a DPF file in the plotter queue ...
Страница 227: ...Field Service Manual December 2003 Page 227 of 276 Stop logging ...
Страница 234: ...Field Service Manual December 2003 Page 234 of 276 ...
Страница 240: ...Field Service Manual December 2003 Page 240 of 276 ...
Страница 242: ...Field Service Manual December 2003 Page 242 of 276 ...
Страница 246: ...Field Service Manual December 2003 Page 246 of 276 ...
Страница 248: ...Field Service Manual December 2003 Page 248 of 276 ...
Страница 252: ...Field Service Manual December 2003 Page 252 of 276 ...
Страница 268: ...Field Service Manual December 2003 Page 268 of 276 ...
Страница 270: ...Field Service Manual December 2003 Page 270 of 276 ...
Страница 274: ...Field Service Manual December 2003 Page 274 of 276 ...