6. EM GUI orientation
6.8
Con
fi
guration Menu > Network resource area
General
This part of the System con
fi
guration page allows listing devices available on the local network and identifying them.
Description
The panel in this area has three tabs:
•
Discovered: Lists all of the devices discovered on the local
network, regardless of the selected System.
•
In use: Lists the devices in the selected System.
•
Comm Setup: If the EM GUI is running on an EC-200
controller, this tab detects and shows if an EC-50 is
connected to the larger controller.
Note: When the Discovered tab is selected, the Event Master
ToolSet Software will continuously send a UDP broadcast over
the network to locate devices (every 5 seconds).
Next to the device name an LED indicates the status of the unit:
•
Yellow : Found in network but not assigned
•
Green: Assigned and currently has an open or active
communication port
•
Red: Assigned but currently has errors trying to communicate
(heart beat communication failure, TCP connection dropped,
etc. )
•
Orange: There is a con
fi
guration error with the unit:
-
Input / Output cards not right justi
fi
ed. Refer to the
corresponding section below of the card placement rules
and error color code.
-
Input / Output con
fi
guration mismatch with the actual unit.
Refer to the corresponding con
fi
guration section of the
card placement rules and error color code.
The small arrow in each device opens a detail menu for the
device, stating most notably the ID of the unit who is used when
units are linked.
In the most of the case, devices are automatically detected and the user just need to add the new device via drag and drop into
the system diagram (see
How to add a device into the selected system
below). But, under certain circumstances in Network
communication the normal UDP based auto detection of Event Master Compatible Devices might not work. A
fi
rewall or a tightly
con
fi
gured switch are examples. In that case a Manual direct TCP/IP request can be sent to a speci
fi
c IP Address (see
How to
manually add a device into the selected system
below).
How to add a device into the selected system
1. Left click on the device to be assigned to the selected system.
2. Drag it to the System diagram area.
98
R5905948 EVENT MASTER DEVICES 17/07/2017
Содержание S3 series
Страница 1: ...Event Master Devices User s Guide R5905948 05 17 07 2017 ...
Страница 9: ...Table of contents Index 531 R5905948 EVENT MASTER DEVICES 17 07 2017 5 ...
Страница 10: ...Table of contents 6 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 20: ...2 Safety 16 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 66: ...4 Hardware orientation 62 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 90: ...5 Front Panel Menu orientation 86 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 264: ...8 Updating firmware 260 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 268: ...9 General operation example Image 9 3 264 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 285: ...9 General operation example Image 9 25 R5905948 EVENT MASTER DEVICES 17 07 2017 281 ...
Страница 288: ...9 General operation example 284 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 316: ...10 Controller orientation 312 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 326: ...11 Controller Configuration 322 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 352: ...12 Controller Operation 348 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 356: ...13 E2 Maintenance 13 2 Process Overview Flow chart Image 13 2 352 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 417: ...13 E2 Maintenance Disregard the heatsink from the spare kit R5905948 EVENT MASTER DEVICES 17 07 2017 413 ...
Страница 418: ...13 E2 Maintenance 414 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 422: ...14 S3 Maintenance 14 2 Process Overview Flow chart Image 14 2 418 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 488: ...16 EC 200 Maintenance 484 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 494: ...17 Environmental information 490 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 512: ...A Specifications 508 R5905948 EVENT MASTER DEVICES 17 07 2017 ...
Страница 527: ...C Troubleshooting C TROUBLESHOOTING R5905948 EVENT MASTER DEVICES 17 07 2017 523 ...
Страница 528: ...C Troubleshooting 524 R5905948 EVENT MASTER DEVICES 17 07 2017 ...