3. Connections
3.4
Communication connection
Overview
•
RS232/422 IN/OUT Serial network
•
•
•
Bi-directional communication port, CTRL 3
3.4.1
RS232/422 IN/OUT Serial network
RS232
An Electronic Industries Association (EIA) serial digital interface standard specifying the characteristics of the commu-
nication path between two devices using either D-SUB 9 pins or D-SUB 25 pins connectors. This standard is used for
relatively short-range communications and does not specify balanced control lines. RS-232 is a serial control standard
with a set number of conductors, data rate, word length and type of connector to be used. The standard speci
fi
es com-
ponent connection standards with regard to computer interface. It is also called RS-232-C, which is the third version
of the RS-232 standard, and is functionally identical to the CCITT V.24 standard. Logical ’0’ is > + 3V, Logical ’1’ is < -
3V. The range between -3V and +3V is the transition zone.
RS422
An EIA serial digital interface standard that speci
fi
es the electrical characteristics of balanced (differential) voltage,
digital interface circuits. This standard is usable over longer distances than RS-232. This signal governs the asyn-
chronous transmission of computer data at speeds of up to 920,000 bits per second. It is also used as the serial port
standard for Macintosh computers. When the difference between the 2 lines is < - 0.2V that equals with a logical ’0’.
When the difference is > +0.2V that equals to a logical ’1’..
Application
1.
Remote control:
-
easy adjustment of projector via a computer.
-
allow storage of multiple projector con
fi
gurations.
-
wide range of control possibilities.
2.
data communication
Pin con
fi
guration
MONITOR OUT
2
1
3
PUSH
2
1
3
PUSH
HARDWIRED REMOTE
10/100 BASE T
SERIAL NETWORK
MONITOR OUT
RS232/422 OUT
RS232/422 IN
WIRELESS REMOTE
CTRL 3
CTRL 2
CTRL 1
PORT 1
PORT 2
BI-DIRECT IONAL
UNI-DIRECTIONAL
Image 3-19
RS232/RS422 serial network connection
RS232/422 Serial Network IN
1
Data Carrier Detect (CD)
6 RXC+
Data Set Ready (DSR)
2 RXC-
Receive Data (RD or RX or RXD)
7
Request to send (RTS)
3 TXC-
Transmitted Data (TD or TX or TXD)
8
Clear To Send (CTS)
4TXC+
Data Terminal Ready (DTR)
9
Ring Indicator (RI)
5 GND
Signal Ground (GND)
-
RS232/422 Serial Network OUT
1
-
6 RXB+
Data Set Ready (DSR)
2 RXB-
Receive Data (RD or RX or RXD)
7
-
3 TXB-
Transmitted Data (TD or TX or TXD)
8
-
R5976690 XLM H25 25/05/2009
31
Содержание R9010100
Страница 1: ...XLM H25 Owner s manual R9010100 R5976690 06 25 05 2009 ...
Страница 8: ...Table of contents 4 R5976690 XLM H25 25 05 2009 ...
Страница 26: ...2 Installation Guidelines 22 R5976690 XLM H25 25 05 2009 ...
Страница 40: ...3 Connections 36 R5976690 XLM H25 25 05 2009 ...
Страница 50: ...4 Getting Started 46 R5976690 XLM H25 25 05 2009 ...
Страница 106: ...7 Installation 102 R5976690 XLM H25 25 05 2009 ...
Страница 126: ...B Standard Source Set up files 122 R5976690 XLM H25 25 05 2009 ...
Страница 136: ...Index 132 R5976690 XLM H25 25 05 2009 ...