Installation Adjustments

7 - 2

5975987 BARCODATA 708 260597

Overview flow chart installation mode.

SCHEIMPFLUG ADJUSTMENT 

<ENTER> to continue
<EXIT> to return

LOOSEN THE 4 
LENS MOUNTING NUTS ON 
EACH LENS, UNTIL THE TAG 
OF EACH SCHEIMPFLUG RING
CAN BE MOVED TO ITS 
DESIRED POSITION
(1.4 M, 2.4 M OR 4.0 M
SCREEN WIDTH°

OPTICAL LENS FOCUSING

<ENTER> to continue
<EXIT> to return

1. LOOSEN THE NUT ON THE 
   REAR OF THE XXXX LENS,
   ROTATE THE LENS BARREL
   TO FOCUS THE CENTER 
   OF THE IMAGE,
   THEN TIGHTEN THE NUT
2. LOOSEN THE NUT ON THE 
   FRONT OF THE XXXX LENS
   AND ROTATE THE FRONT 
   SECTION OF THE LENS TO 
   FOCUS THE CORNERS OF THE 
   IMAGE, THEN TIGHTEN THE NUT.

This menu is repeated 3
times, first in Green,
then in Red and then in
Blue

RASTER CENTERING 

<ENTER> to continue
<EXIT> to return

CONTRAST LEVEL IS REDUCED
AND BRIGHTNESS INCREASED
TO MAKE THE RASTER 
VISIBLE ON THE FACE PLATE 
OF EACH CRT.

USE THE ARROW KEYS
TO CENTER THE RASTER
ON THE GREEN, RED AND 
BLUE CRT RESPECTIVELY

This menu is displayed in green.  After ENTER is
pressed, only the green raster is displayed and the
control disk may be used to center the raster on the
CRT surface.  This menu is also displayed, once in
red and once in blue.

CRT PROJECTION ANGLE

ADJUSTMENT

<ENTER> to read more

<EXIT> to return

CRT PROJECTION ANGLE IS 
THE FIRST STEP OF STATIC 
CONVERGENCE ADJUSTMENT.

IT IS CRITICAL THAT THE 
RASTERS ARE CENTERED ON
THE CRT FACE PLATES 
PRIOR TO PERFORMING
THIS STEP.
...

CRT PROJECTION ANGLE

ADJUSTMENT

<ENTER> to continue
<EXIT> to return

DURING THIS PROCEDURE,
RED ON GREEN AND THEN 
BLUE ON GREEN CROSSHAIRS
WILL BE DISPLAYED
TO ALLOW THE RED AND 
BLUE CRTS TO BE ALIGNED
WITH THE GREEN CRT.

LOOSEN BOLTS A AND B
TO PIVOT THE RED CRT,
AND BOLDS C AND D
TO PIVOT THE BLUE CRT.

CRT 

PROJECTION ANGLE

ADJUSTMENT

Align crosshairs

<ENTER> continue
<EXIT> to return

Installation mode start up

It will be necessary to perform several mechanical adjustments while
in the installation mode.  Remove the top cover in order to gain
access to the adjustment points (see  Access to controls).
Two possible ways to enter the installation mode :

a) Using the RCU.

Press the 

ADJUST key.

The projector displays the path selection menu.

b) Using the local keypad.

Press the 

ADJUST key.

The projector displays the 

General access menu.

ADJUST

STANDBY

ENTER

EXIT

GENERAL ACCESS

Select with       ,
                        or
then <ENTER>.

<EXIT> to return

SHARPNESS

TINT

COLOR

BRIGHTNESS

CONTRAST

 

        4

1          2

Enter ADJUST

Use the control disk to highlight 

enter ADJUST and press ENTER.

The path selection menu will be displayed.

Содержание R9002120

Страница 1: ...R9002120 INSTALLATION MANUAL DATA 708...

Страница 2: ......

Страница 3: ...BARCO PROJECTION SYSTEMS Date 260597 Art No R5975987 R9002120 INSTALLATION MANUAL DATA 708...

Страница 4: ...on in this manual is subject to change without notice Produced by BARCO NV May 1997 All rights reserved Trademarks are the rights of their respective owners BARCO nv Projection Systems Noordlaan 5 B 8...

Страница 5: ...the projector 3 2 How to install the projector 3 2 INSTALLATION SET UP 4 1 Access to controls 4 1 Scan adaptation 4 2 PROJECTOR SET UP 5 1 Projector Set Up 5 1 Password mode 5 1 POWER MAINS CONNECTION...

Страница 6: ...Table of Contents i 2 5975987 BARCODATA 708 260597...

Страница 7: ...you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the purpose of the grounding type plug WARNING FOR THE CUSTOMERS THIS APPARATUS...

Страница 8: ...he power cord or plug is damaged or frayed b If liquid has been spilled into the equipment c If the product has been exposed to rain or water d If the product does not operate normally when the operat...

Страница 9: ...packing material they will come in handy if you ever have to ship your projector For maximum protection repack your projector as it was originally packed at the factory To open de banding pull on the...

Страница 10: ...Unpacking and Dimensions 2 2 5975987 BARCODATA 708 260597 Projector dimensions mm...

Страница 11: ...rtant As a general rule darken the room to the point where there is just sufficient light to read or write comfortably Spot lighting is desirable for illuminating small areas so that interference with...

Страница 12: ...ceiling screen width SW Front view Top view Formulas for Projector to screen distance and correction value A with regard to the screen width for HD145 lenses metric Formulas metric PD m 1 21 x SW m 0...

Страница 13: ...upport the top cover with the hand no support is incorporated During some installations it will become handy to remove the top cover totally Therefore pivote the top cover 60 push the top cover to the...

Страница 14: ...FFPROJECTORANDUNPLUGTHEPOWERCORD BEFORE CHANGING THE SCAN DIRECTION Gaining access to the scan connectors and the convergence con nectors Open the top cover to remove it see Gaining access to controls...

Страница 15: ...t connector position Note this check procedure can only be done after power mains connection So first continue with the projector set up and the connections and then return to this checking procedure...

Страница 16: ...Installation Set Up 4 4 5975977 BARCODATA 708 260597...

Страница 17: ...DEO RS232 OUT RS232 IN strap Password mode With a strap on the controller unit the important projector adjustments can be protected with a password When the password feature is enabled strap mounted o...

Страница 18: ...Projector Set Up 5 2 5975987 BARCODATA 708 260597...

Страница 19: ...V NOM 120 230 Volt I MAX 5 2 5 AMP FREQ 60 50 Hz OFF ON Input power mains voltage adaptation Attention The BARCODATA 708 R9002120 leaves the factory to operate on a mains power input of 230 Vac Adapta...

Страница 20: ...sonnel Fuse type 2 x T5A 250V Barco order number R314104 Switching on off The projector is switched ON and OFF using the power mains switch ON OFF Pressed ON Not pressed OFF The projector can start no...

Страница 21: ...e adjustment mode ADJUSTMENT MODE Select a path from below Select with or then ENTER EXIT to return GUIDED RANDOM ACCESS INSTALLATION SERVICE IRIS source 1 Random Access Adjustment Guided Adjustment I...

Страница 22: ...d once in red and once in blue CRT PROJECTION ANGLE ADJUSTMENT ENTER to read more EXIT to return CRT PROJECTION ANGLE IS THE FIRST STEP OF STATIC CONVERGENCE ADJUSTMENT IT IS CRITICAL THAT THE RASTERS...

Страница 23: ...turns to the path selection menu When the password mode is active your password will be asked Your password contains 4 digits a Adjusting the projector with the RCU Enter the digits with the numeric k...

Страница 24: ...126 range 3 min SW 3 20 m 126 max SW 6 00m 236 1 Open the top cover see Gaining access to controls 2 Loosen the lens bolts do not remove them and slide the lens to the front until the scheimflug ring...

Страница 25: ...g the wing nut at the rear end of the lens and rotating the lens barrel until the center of the image is clearly focused The corners of the projected image are focused by loosening the wing nut at the...

Страница 26: ...RT faceplate RASTER CENTERING ENTER to continue EXIT to return CONTRAST LEVEL IS REDUCED AND BRIGHTNESS INCREASED TO MAKE THE RASTER VISIBLE ON THE FACE PLATE OF EACH CRT USE THE ARROW KEYS TO CENTER...

Страница 27: ...2 SW1 The same projection angle is mis aligned for new screen width SW2 Re alignment is necessary Each screen width change requires readjust ment of the projection angle Projection angle correctly ali...

Страница 28: ...en crosshair Move the red CRT totheoutside away fromthegreenCRT Move the red CRT towards the green CRT ENTER continues to blue and green crosshairs EXIT will return to CRT projection angle adjustment...

Страница 29: ...t of the projector Overview of the corrections For detailed information about these corrections and procedures to be followed see owner s manual pages given hereafter are for the random access adjustm...

Страница 30: ...Installation Adjustments 7 10 5975987 BARCODATA 708 260597...

Страница 31: ...de menu Highlight G2 adjust and press ENTER Select with or then ENTER EXIT to return COMMON SETTINGS G2 ADJUSTMENT CRT RUN IN CYCLE PROJECTOR WARM UP A safety notice will be displayed to warn the oper...

Страница 32: ...the G2 potentiometers very slowly with a screwdriver until the corresponding LED just stops illuminating Repeat the adjustment for the other colors Once the three G2 potentiometers have been correctl...

Страница 33: ...AL FIRE PROTECTION ASSOCIATION STD 704M SIGNAL TRESHOLD LIMIT VALUE Units TRESHOLD LIMIT VALUE Units BASE METAL ALLOYS METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX OTHERS MATERIAL SAFETY D...

Страница 34: ...OR THE RESULTS TO BE OBTAINED FROM THE USE THEREOF VENDOR ASSUMES NO RESPONSABILITY FOR INJURY TO VENDEE OR THIRD PERSONS PROXIMATELY CAUSED BY THE MATERIAL IF REASONABLE SAFETY PROCEDURES ARE NOT ADH...

Отзывы: