background image

560424   BARCO Quick (E)

Button for Basic Operations

Operation panel 1

FREEZE button

Press to freeze the image on the screen when changing the

documents. When the Freeze function is active, the freeze mark

 is displayed.  Press again to release the Freeze function.

• The Freeze function is valid only for the monitor or projector

screen connected to the RGB connector of this unit.

• This button is also used for menu operations from the operation

panel.

ZOOM W/T buttons

To adjust the size of the image.

Press the ZOOM T button to enlarge the image.

Press the ZOOM W button to widen the area to be captured.

• These buttons are also used for menu operations from the operation

panel.

FOCUS 

/

 9

 buttons

Press to focus on the document.

For automatic focusing, press both buttons simultaneously.

• These buttons are also used for menu operations from the operation

panel.

MENU button

Press to turn the menu display on/off.

REVERSE button, NEGA and BLUE indicators

For a negative image, press the button.

Each time you press the button, the display changes in the sequence:

Normal 

H

 Black & White Reversal (NEGA indicator lights) 

H

 Blue

display (BLUE indicator lights) 

H

 Normal, and so on.

BRIGHTNESS buttons

Press to adjust the brightness of

the screen.

POWER indicator

It lights when the power is on.

E-ZOOM button/indicator

Press the button to activate the electronic zoom function. The

indicator lights, and the image is enlarged 2 or 4 times. When

you press the button again, the function is deactivated, and the

indicator goes dark.

TONE button/indicator

Press the button to sharpen the image. The indicator lights.

When you press the button again, the TONE function is deactivated

and the indicator goes dark.  Using the menu, fine adjustment in 5

steps can be made.

LIGHTS button/UPPER and LOWER

indicators

Press the button to light the fluorescent lamps.

Each time you press the button, the illumination

changes in the sequence:  Upper lamps on

(UPPER indicator lights) 

H

 Lower lamps on

(LOWER indicator lights) 

H

 Both off, and so on.

Operation panel 2

POWER

 switch

Quick Reference

2001.1.9, 9:48 AM

Содержание Preca 1280

Страница 1: ...LUE indicators For a negative image press the button Each time you press the button the display changes in the sequence Normal H Black White Reversal NEGA indicator lights H Blue display BLUE indicator lights H Normal and so on BRIGHTNESS buttons Press to adjust the brightness of the screen POWER indicator It lights when the power is on E ZOOM button indicator Press the button to activate the elec...

Страница 2: ...or on the rear of this unit For details refer to page 13 of the User s Manual 2 Turn on the unit Press the POWER switch down to the side 3 Turn on the monitor or projector For details refer to the operation manual for the connected equipment 4 Perform the input selection on the monitor or projector Set it so that the picture from this unit is displayed 5 Turn on the lamps Press the LIGHTS button P...

Страница 3: ...le holding the left mouse button pressed The lines drawn with the Pen function will disappear when another image on the PC card is displayed To deactivate the Pen function click the right mouse button For details on PC cards refer to pages 33 to 37 of the User s Manual L For a clear image Press the TONE button The contrast of the image is emphasized making the image clear L Using the electronic zo...

Страница 4: ... For documents with fine characters Linear2 For glossy documents the brightness will be decreased Picture For photos and colour printed matters L Sharpness To adjust the image contours which can be adjusted in 6 steps L Iris A M To alternately select automatic and manual iris adjustments for the camera Normally select Auto Auto Exp ON To activate the Auto Iris function Auto Exp OFF To deactivate t...

Страница 5: ... BARCO ï ï E 2000 7 18 8 12 PM 44 45 ...

Страница 6: ...hly to ensure safe and proper operation of the unit The precautions given here contain important instructions to ensure safe usage of the product Be sure to observe these precautions KEEP THIS MANUAL HANDY FOR ANYONE WHO USES THE UNIT Failure to observe this instruction could lead to personal injury and or property damage The symbols used in this manual have the meanings described below Examples o...

Страница 7: ...ZOOM W T FREEZE AF CARD MENU MENU Main Unit Continue Light arms pp 15 16 17 19 To light the document stage Document stage p 19 Place a document on the stage Fluorescent lamps are built in under the stage and are used for transparent documents Camera head pp 15 16 To shoot the document Light arms pp 15 16 17 19 To light the document stage Camera arms pp 15 16 For holding the camera head Stopper pp ...

Страница 8: ...ime you press the button the illumination changes in the sequence Upper lamps on the UPPER indicator lights Lower lamps on the LOWER indicator lights Both off and so on E ZOOM button indicator p 19 Press the button to activate the electronic zoom function The indicator lights and the image is enlarged 2 or 4 times When you press the button again the function is deactivated and the indicator goes d...

Страница 9: ...ecting a Projector and Monitor 13 Connecting a PC Ethernet 14 Connecting the Mouse 14 LPREPARATIONS 15 Raising the Camera Head and Light Arms 15 To Fold the Camera Arm and Light Stands 16 Attaching the Fluorescent Lamps 17 Connecting the Power Cord 17 Operation LShooting a Document 18 LUsing Menus 21 Items to be Adjusted Using Menus 24 LConnecting to a Network 32 LUsing a PC Card 33 Using the PC C...

Страница 10: ...ronic zoom pp 19 20 21 31 36 In addition to the freeze white balance auto focus color compensation gamma compensation and image inver sion functions the electronic zoom function up to 4x is provided In combination with the optical 6x zoom 24x zoom at maximum can be obtained Input of transparent materials p 18 The unit is equipped with a special lighting device that enables easy capturing of transp...

Страница 11: ...lied to the video input S video cable supplied to the S video input D sub 15 pin cable supplied to the 15 pin connector Monitor Projector Signal flow TV receiver Using a screwdriver tighten the screws of the RGB connector Connecting a Projector and Monitor Before connection be sure to turn the power to this unit and the device to be connected off Depending on the device to be connected use the RGB...

Страница 12: ...t the administrator of the network For information on network settings see Connecting to a Network p 32 10Base T REMOTE Using a screwdriver tighten the screws of the REMOTE connector Rear of this unit Signal flow PC to the RS 232C connector to the Ethernet connector Commercially available Ethernet cable Commercially available RS 232C cable Note The connection to the REMOTE connector is required on...

Страница 13: ...procedure of Raising the camera arm and light stands p 15 4 Fold the light stands Fold the light stands with the fluorescent lamps facing the document stage Fold the right stand first Then fold the left stand 5 While holding the stopper pressed fold the camera arm until a clicking sound is heard 2 Draw in the camera arm 3 While holding the stopper pressed raise the camera arm until it stands verti...

Страница 14: ...r details refer to the operation manual for the connected equipment The same operation can be performed using the menu p 24 Note When turning the power off then on again leave it off for at least 10 sec onds before turning it back on ZOOM T button Press to enlarge the image max 6 times Continue Adjust the image size by pressing the ZOOM W or T button When you hold the ZOOM W or T button pressed th...

Страница 15: ...n 3 Press the FREEZE button Press the button before removing the material The image will be frozen on the screen 1 You can draw lines on the screen using a mouse for smooth presentations p 33 To use the Pen function Shooting a Document Continued Using Menus For efficient use of this unit the following 14 menu icons are provided There are two methods for displaying and operating the menu icons usin...

Страница 16: ... fifth of the screen of the screen and click the right mouse button 2 Move the pointer and se lect the menu icon The status settings of the menu items etc of the selected menu is displayed beneath the icon Using the mouse 3 Click the left mouse button left click You can now change setting values on the selected menu Example When adjusting COLOR To clear the menu icons Move the pointer anywhere oth...

Страница 17: ...justed the Gain and Color settings return to the factory set values L Tone To adjust the tone gamma setting Natural Linear1 Document Linear2 Picture Using the TONE button on operation panel 2 you can toggle the setting between Standard Natural and HI Document n WBset Tone Reverse Color Shar nes Continue Using Menus Using the mouse 1 Left click the Lights menu icon Each left click changes the setti...

Страница 18: ... FOCUS 8 or 9 button to select the color to be adjusted Buttons appears at the left and right ends of the adjust ment bar for the selected color 2 Press either the ZOOM W or T button to ad just the color The value set on the adjustment bar changes 3 To adjust other colors repeat step 1 and 2 4 Press the FREEZE button to register your ad justment 5 Press the FREEZE button The adjustment bar disappe...

Страница 19: ... The Fit Over function does not operate in SXGA mode L Change Pointer To change the form and color of the pointer Fit Over Fit To display the full screen Over To display the center area Iris A M Fit Over Change Pointer Save to card Save to Server Using Menus Form Color Yellow White Blue Using the mouse 1 Left click the Fit Over menu icon Each left click changes the setting as shown above 2 Click t...

Страница 20: ...rk Setting Set the items relating to networking PowerOn Setting SAVE n o p q r s t u v w x y z a b c d e f g h i j k l m skip 0 1 2 3 4 5 6 7 8 9 Default NetWork Setting Enable NetWork Enable FTP Client Read Only FTP WEB disable Write Control NetWork Setting Internal Server 192 168 001 002 IP Address 255 255 000 000 SubNet Mask User ID anonymous max 10 char Pass Word none max 10 char External Serv...

Страница 21: ...User ID and Password p 30 2 Click the button for downloading image files which is displayed in the upper portion of the screen when the network is connected The Web camera display appears 3 Click the download button in the lower portion of the screen L Getting with an FTP command You can obtain a file using FTP Get 1 Issue the Is command The RAMIBOX and CARDIBOX appear 2 Execute cd RAMIBOX 3 Issue...

Страница 22: ...nu but ton using the ZOOM W T button 3 Press the FREEZE button The selection of the PC Card menu button is ex ecuted 1 Move the pointer to the lower area lower four fifths of the screen of the screen and click the right mouse button 2 Move the pointer to a PC Card menu button 3 Click the left mouse button The selection of the PC Card menu button is ex ecuted LTo clear the PC Card menu Move the poi...

Страница 23: ... menu on a monitor or projector connected to the RGB connector The monitor to display the PC card menu can be speci fied using the Setup menu p 29 L ZOOM button To enlarge the image from a PC card file on the screen Each left click changes the size as follows When you move the pointer to an area outside the image while the electronic zoom is active the screen automatically scrolls L Slide Show Del...

Страница 24: ...Fluorescent Lamps The fluorescent lamps used with this unit are commercially available When a lamp has burned out purchase one by specifying the type name FPL13EX N Cleaning the Main Unit To remove dirt from the cabinet lightly wipe the surface with a soft cloth For adhered dirt wipe with a cloth soaked with neutral detergent diluted with water and wrung tight Then wipe the surface with a dry clot...

Страница 25: ... not go on No picture is obtained The picture is not clear The picture is not fully displayed Pale or muddy colors Measures Check that the power cable is not disconnected from the AC outlet or the AC power input receptacle of the unit p 17 Check that the cables are firmly connected pp 13 14 Check that the cable is firmly connected to the appropriate receptacle of the equipment to be used in combin...

Страница 26: ...0 020 Hz XGA H 48 363 kHz V 60 004 Hz NTSC H 15 734 kHz V 59 94 Hz PAL H 15 625 kHz V 50 Hz PC card Applicable cards PCMCIA ATA Type II flash card Recording format Conforms to JPEG BMP General Dimensions 693 w 510 d 640 h mm 27 w 20 d 25 h inches in use 435 w 510 d 144 h mm 17 w 20 d 5 6 h inches in storage Weight Approx 10 0 kg 22 05 lbs main unit Power requirements 100 240 V AC 50 60 Hz Power co...