7
About this document
This installation manual explains how to replace malfunction HDD(s) of the Barco ICMP (Integrated Cinema
Media Processor) installed in the field.
Clarification of term
“
ICMP
”
used in this document
When referring in this document to the term
“
ICMP
”
means that the content is applicable for following Barco
products:
•
ICMP
•
ICMP-X
CAUTION:
Not withstanding the HDDs are technical hot swappable it is strongly advised to switch
off the projector prior to replace the HDD.
Removing a HDD while power is on will degrade the RAID configuration, inserting a HDD will cause
a performance drop in case of a playout, putting a set of HDD
’
s in the projector one by one when
power is on might trigger an unnecessary rebuild,
…
In case only one HDD is replaced (RAID degraded mode) the ICMP automatically starts with the
RAID recovery process after the malfunction HDD is replaced. The red LED of the HDD which has
to be rebuilt is blinking. Rebuild process takes about 3 to 4 hours for 1TB HDD and could takes
about 13 to 14 hours for 4TB HDD. Once the RAID is completed the red LED turns off.
CAUTION:
It's strongly recommended to complete the RAID recovery process prior to starting a
show. This to ensure that the content integrity is preserved and that the show is not interrupted.
In case more than one HDD must be replaced, the RAID is 'broken'. All content will be lost. Once
the HDDs are replaced, when the projector restarts, the ICMP automatically creates a new (empty)
RAID 5 configuration.
Overview
•
•
•
What are the possible HDD swaps
•
•
•
Installing a HDD into the ICMP
R5905769 /04