4. Installation procedures
4.7
Installing the RJ45 IP66 protection shells
The IP66 protection shells can be installed upon the RJ45 plug of standard UTP network cables. The network
cables used between FLX-NNI Controller and FLX-HUB must be of the type UTP cat 6. The maximum length
may not exceed 100 meter.
C
AUTION
:
The network cable which has to be plugged into the RJ45 socket of the FLX-HUB must be equipped
with IP66 protection shells.
How to install the IP66 protection shells on a standard UTP network cable?
1. Align the 7 parts as illustrated.
1
2
3
4
5
6
7
Image 4-7
2. Slide part 1 and 3 over the RJ45 connector.
3. Place the sealing rubber (part 2) over the cable, between part 1 and part 3, and slide it into part 3.
4. Place the O-ring (part 4) over the RJ45 connector into part 3.
5. Place the long sealing rubber (part 5) over the cable between part 3 and the RJ45 plug.
1
2
3
4
5
6
7
Image 4-8
6. Slide the long sealing rubber (part 5) against the RJ45 plug and then slide part 3 against the long sealing rubber.
Image 4-9
7. Place part 6 over the RJ45 plug and fasten with part 7.
Image 4-10
8. Fasten the back end of the shell with part 1.
R59770420 FLX-24 21/12/2009
51
Содержание FLX-24
Страница 1: ...FLX 24 Installation manual R59770420 00 21 12 2009...
Страница 6: ...Table of contents 2 R59770420 FLX 24 21 12 2009...
Страница 46: ...3 Components of an FLX display system 42 R59770420 FLX 24 21 12 2009...
Страница 56: ...4 Installation procedures Image 4 11 52 R59770420 FLX 24 21 12 2009...
Страница 72: ...B Specifications 68 R59770420 FLX 24 21 12 2009...
Страница 76: ...Index T This controller 24 U User interface 22 W Weight 67 Parts 67 72 R59770420 FLX 24 21 12 2009...