27. Lamp power supply
27.1 LPS diagnostic LED’s
Status LED’s on LPS unit
The LPS module contains in total 10 status LED’s. 5 LED’s per LPS unit. One orange, three green and one red LED. The orange
LED “LVPS OK” lights up immediately after the projector is switched on. All other status LED’s of the LPS unit remains off. This is
the standby status of the LPS unit. Once the command is send to the LPS units to start up the projector lamp the green LED’s are
lighting up one after the other. First the green LED “PFC OK”, then the green LED “LPS OK” and finally, when the lamp is ignited,
the green LED “LAMP ON”.
The red LED “ERR” remains off unless an error is detected inside the LPS unit or both LPS units where ordered to shutdown due to
a malfunction somewhere else inside the projector.
LAMP OUT
MAINS
INPUT
LAMP OUT
MAINS
INPUT
LAMP ON / LVPS OK
ERR PFC
OK
LPS
OK
Image 27-2
Diagnostic
Or.
Gr.
Gr.
Gr.
Re.
LVPS OK
PFC OK
LPS OK
LAMP
OK
ERR
Diagnostic
Action
OFF
OFF
OFF
OFF
OFF
No input voltage.
Switch on the projector.
ON
OFF
OFF
OFF
OFF
Standby modus of LPS unit.
—
ON
ON
ON
OFF
OFF
PFC and LPS seems to work
normally but the lamp is not
ignited. This situation can be
the result of a bad lamp or
SPG module.
•
Install another FLM
lamp house in case the
voltage on the “LAMP
OUT” pins is 140 volt
and you hear the SPG
module three times
clicking to ignite the
lamp.
•
Replace the SPG
module in case the
voltage value on the
“LAMP OUT” pins is 140
volt and you do not hear
the SPG module clicking
to ignite the lamp.
•
Replace the LPS
module in case the
voltage value on the
“LAMP OUT” pins is
below 140 volt and the
lamp is not ignited.
ON
ON
ON
ON
OFF
LPS unit is operating
normally. Projector lamp
is ignited.
—
R59770072 FLM SERIES 19/03/2007
299
Содержание FLM series
Страница 1: ...FLM series Service manual R59770072 00 19 03 2007...
Страница 6: ...Table of contents 4 R59770072 FLM SERIES 19 03 2007...
Страница 10: ...1 Safety 8 R59770072 FLM SERIES 19 03 2007...
Страница 11: ...2 General info 2 GENERAL INFO Overview Location of modules Spare part kits R59770072 FLM SERIES 19 03 2007 9...
Страница 86: ...6 Removal and installation of projector covers 84 R59770072 FLM SERIES 19 03 2007...
Страница 96: ...8 Lamp and lamp house 94 R59770072 FLM SERIES 19 03 2007...
Страница 102: ...9 Input communication unit 100 R59770072 FLM SERIES 19 03 2007...
Страница 125: ...13 Cold mirror assembly Image 13 5 Remove of cold mirror R59770072 FLM SERIES 19 03 2007 123...
Страница 130: ...13 Cold mirror assembly 8 Reinstall the side cover 128 R59770072 FLM SERIES 19 03 2007...
Страница 133: ...14 Lens holder F Image 14 4 R59770072 FLM SERIES 19 03 2007 131...
Страница 136: ...14 Lens holder Image 14 10 The lens holder has to be adjusted after installation 134 R59770072 FLM SERIES 19 03 2007...
Страница 140: ...14 Lens holder 138 R59770072 FLM SERIES 19 03 2007...
Страница 150: ...15 Vertical and Horizontal shift motors Image 15 13 Remove motor Image 15 14 148 R59770072 FLM SERIES 19 03 2007...
Страница 154: ...15 Vertical and Horizontal shift motors 152 R59770072 FLM SERIES 19 03 2007...
Страница 180: ...16 FLM liquid cooling circuit 178 R59770072 FLM SERIES 19 03 2007...
Страница 190: ...17 Heat exchanger 188 R59770072 FLM SERIES 19 03 2007...
Страница 204: ...18 Cooling pump 202 R59770072 FLM SERIES 19 03 2007...
Страница 208: ...19 Shutter replacement 206 R59770072 FLM SERIES 19 03 2007...
Страница 212: ...20 Formatter Interface Board 210 R59770072 FLM SERIES 19 03 2007...
Страница 217: ...21 Pixel map processor board Image 21 7 PMP removal R59770072 FLM SERIES 19 03 2007 215...
Страница 220: ...21 Pixel map processor board 218 R59770072 FLM SERIES 19 03 2007...
Страница 228: ...22 LCD panel replacement 226 R59770072 FLM SERIES 19 03 2007...
Страница 234: ...23 Keypad board replacement 232 R59770072 FLM SERIES 19 03 2007...
Страница 288: ...25 Peltier replacement 286 R59770072 FLM SERIES 19 03 2007...
Страница 314: ...28 Start pulse generator 312 R59770072 FLM SERIES 19 03 2007...
Страница 326: ...Glossary 324 R59770072 FLM SERIES 19 03 2007...