17. Troubleshooting
Code E9000201: “PSU Standby 12V exceeded” (Error)
Situation
Solution
Potential malfunction of the PSU:
12V_Stby voltage exceeded.
Replace the PSU. See service procedure .
Code E9000300: “PSU ThermalHub low limit reached” (Error)
Situation
Solution
Potential malfunction of the PSU:
Thermal Hub 12V voltage to low.
Replace the PSU. See service procedure .
Code E9000301: “PSU ThermalHub high limit reached” (Error)
Situation
Solution
Potential malfunction of the PSU:
Thermal Hub 12V voltage to high.
Replace the PSU. See service procedure .
Code E9000400: “PSU Fan low limit reached” (Error)
Situation
Solution
Potential malfunction of the PSU:
Fan not spinning.
•
Verify if the fan is not blocked.
•
Check the fan wiring.
Code E9000501: “PSU Heatsink1 temperature exceeded” (Error)
Situation
Solution
Potential malfunction of the PSU:
Heatsink1 temp too high.
•
Verify if the fan is not blocked.
•
Check the fan wiring.
•
Replace the PSU. See service procedure .
Code E9000601: “PSU Heatsink2 temperature exceeded” (Error)
Situation
Solution
Potential malfunction of the PSU:
Heatsink2 temp too high.
•
Verify if the fan is not blocked.
•
Check the fan wiring.
•
Replace the PSU. See service procedure .
Code L80000: “Illumination laser was switched off unexpectedly” (Error)
Situation
Solution
Light Source switched off due to
other Light Source related errors
This error will appear together with other errors. Solve those errors
fi
rst.
Code L80001: “Illumination laser communication error” (Error)
Situation
Solution
Communication error with the
light source or one of its linked
components
This error will appear together with other communication errors. Solve those errors
fi
rst.
Code L80003: “Autodimming: Set maximum illumination power limit for source ’laser’ to 20 %”
(Warning)
Situation
Solution
An error has caused the Light
Source to be dimmed to its minimum
output
This warning will appear together with other errors. Solve those errors
fi
rst.
74
723–0016 F90 01/12/2017
Содержание F90 series
Страница 1: ...F90 Service Manual 723 0016 02 01 12 2017...
Страница 6: ...Table of contents 4 723 0016 F90 01 12 2017...
Страница 8: ...1 Introduction 6 723 0016 F90 01 12 2017...
Страница 10: ...2 General safety 8 723 0016 F90 01 12 2017...
Страница 18: ...4 DLP System General Description 16 723 0016 F90 01 12 2017...
Страница 25: ...5 GP6 system functional description Image 5 5 723 0016 F90 01 12 2017 23...
Страница 28: ...5 GP6 system functional description 26 723 0016 F90 01 12 2017...
Страница 34: ...7 OSD display menu 32 723 0016 F90 01 12 2017...
Страница 36: ...8 Thermal management system Image 8 1 34 723 0016 F90 01 12 2017...
Страница 42: ...8 Thermal management system 40 723 0016 F90 01 12 2017...
Страница 58: ...14 XPS actuator 56 723 0016 F90 01 12 2017...
Страница 60: ...15 Light engine 58 723 0016 F90 01 12 2017...
Страница 82: ...18 Assembly Hierarchy 80 723 0016 F90 01 12 2017...
Страница 103: ...20 Scheduled operations Image 20 42 Image 20 43 723 0016 F90 01 12 2017 101...
Страница 104: ...20 Scheduled operations 102 723 0016 F90 01 12 2017...
Страница 112: ...21 DMD DMD Board CLGA DMD heatsink elements 110 723 0016 F90 01 12 2017...
Страница 132: ...24 Lens shift assembly 130 723 0016 F90 01 12 2017...
Страница 134: ...25 Prism Housing Image 25 5 132 723 0016 F90 01 12 2017...