17. Troubleshooting
Code E4000700: “Radiator Fan 4 speed too low” (Error)
Situation
Solution
Blocked fan
Remove the fan from the radiator assembly and verify if the fan is not blocked. .
Wiring issue
Check the connection towards the thermal hub board. If problem persists, replace the
fan.
Fan end of life.
Replace the fan.
Code E4000900: “Peltier Element temperature too low”
Situation
Solution
Peltier element cooling red laser part
not functioning
Check the wiring towards the thermal hub.
Code E7000001: “DMD temperature exceeded” (Error)
Situation
Solution
DMD temperature exceeded due to
DMD cooling system malfunction.
•
Check if the cooling circuit of the Light Processor is connected with the pump and
heat exchanger.
•
Check if the 4 screws that hold the cold plate to the back of the DMD board, are
tightened.
Code E8000001: “Colorwheel temperature exceeded” (Error)
Situation
Solution
ColorWheel temperature exceeded.
Check if the cooling circuit of the Light source is connected with the pump and heat
exchanger.
Code E9000000: “PSU mainpower low limit reached” (Error)
Situation
Solution
Internal Power Supply not functioning
well due to incoming mains voltage
too low .
Check if the power cord correctly plug into the power input socket of the projector and if it
is correctly plug into a grounded AC outlet.
Code E9000001: “ PSU mainpower exceeded” (Error)
Situation
Solution
Internal Power Supply not functioning
well due to incoming mains voltage
too high .
Check if the power cord correctly plug into the power input socket of the projector and if it
is correctly plug into a grounded AC outlet.
Code E9000100: “PSU Mainboard 12V low limit reached” (Error)
Situation
Solution
Potential malfunction of the PSU:
Main 12V Minimal voltage not
available.
Replace the PSU.
Code E9000101: “PSU Mainboard 12V exceeded” (Error)
Situation
Solution
Potential malfunction of the PSU:
Main 12V voltage exceeded.
Replace the PSU..
Code E9000200: “PSU Standby 12V lower limit reached” (Error)
Situation
Solution
Potential malfunction of the PSU:
12V_Stby Minimal voltage not
available.
Replace the PSU. See service procedure .
723–0016 F90 01/12/2017
73
Содержание F90 series
Страница 1: ...F90 Service Manual 723 0016 02 01 12 2017...
Страница 6: ...Table of contents 4 723 0016 F90 01 12 2017...
Страница 8: ...1 Introduction 6 723 0016 F90 01 12 2017...
Страница 10: ...2 General safety 8 723 0016 F90 01 12 2017...
Страница 18: ...4 DLP System General Description 16 723 0016 F90 01 12 2017...
Страница 25: ...5 GP6 system functional description Image 5 5 723 0016 F90 01 12 2017 23...
Страница 28: ...5 GP6 system functional description 26 723 0016 F90 01 12 2017...
Страница 34: ...7 OSD display menu 32 723 0016 F90 01 12 2017...
Страница 36: ...8 Thermal management system Image 8 1 34 723 0016 F90 01 12 2017...
Страница 42: ...8 Thermal management system 40 723 0016 F90 01 12 2017...
Страница 58: ...14 XPS actuator 56 723 0016 F90 01 12 2017...
Страница 60: ...15 Light engine 58 723 0016 F90 01 12 2017...
Страница 82: ...18 Assembly Hierarchy 80 723 0016 F90 01 12 2017...
Страница 103: ...20 Scheduled operations Image 20 42 Image 20 43 723 0016 F90 01 12 2017 101...
Страница 104: ...20 Scheduled operations 102 723 0016 F90 01 12 2017...
Страница 112: ...21 DMD DMD Board CLGA DMD heatsink elements 110 723 0016 F90 01 12 2017...
Страница 132: ...24 Lens shift assembly 130 723 0016 F90 01 12 2017...
Страница 134: ...25 Prism Housing Image 25 5 132 723 0016 F90 01 12 2017...