13.1 Procedure
1.
Enter Prospector, and select login.
Enter the service code.
2.
Select the Service menu/Native RealColorP7
3.
Click on the white radio button, and enable the
“
Test Pattern
”
switch
Image 13-1
4.
Go to the Laser pulsing slider.
5.
d. Measure what the y white value is and increase the blue laser value if the y value is higher than 0.329 and
reduce it if
’
s lower than 0.329 The goal is to set the laser pulse value so that the white ypoint is 0.329
6.
Go back to the native RealColor P7 menu item and update the x and y value for white to match the value you
read from the meter.
Write down the LUX/Foot Lambert value
7.
Click on the red radio button and measure x, y and lux/foot lambert value
•
Add the x and y value into the menu and write down the red lux/foot lambert value.
•
Take the red luminance value and divide it by white RED/WHITE
•
Write the result into the red luminance field in prospector
Содержание F70 Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Service manual F70...
Страница 7: ...723 0018 02 F70 7 22 5 3 Reassemble the TIR prism 163 23 Prism Housing 165 23 1 Prism Housing 166...
Страница 8: ...723 0018 02 F70 8...
Страница 11: ...11 723 0018 02 F70 General safety 2...
Страница 14: ...723 0018 02 F70 14 General safety...
Страница 21: ...21 723 0018 02 F70 DLP System General Description 4...
Страница 26: ...723 0018 02 F70 26 DLP System General Description...
Страница 36: ...723 0018 02 F70 36 GP7 system functional description...
Страница 40: ...723 0018 02 F70 40 GP7 periodic maintenance...
Страница 44: ...723 0018 02 F70 44 OSD display menu...
Страница 53: ...723 0018 02 F70 53 Long Lifetime setting 0m asl Image 8 7 Thermal management system...
Страница 54: ...723 0018 02 F70 54 Thermal management system...
Страница 58: ...723 0018 02 F70 58 Lenses and adjustment...
Страница 59: ...59 723 0018 02 F70 Optical adjustments 10...
Страница 65: ...723 0018 02 F70 65 Image 11 2 Picture distortion Colorwheels...
Страница 66: ...723 0018 02 F70 66 Colorwheels...
Страница 67: ...67 723 0018 02 F70 Phosphor wheel 12...
Страница 70: ...723 0018 02 F70 70 Phosphor wheel...
Страница 71: ...71 723 0018 02 F70 Laser pulsing adjustment 13...
Страница 74: ...723 0018 02 F70 74 Laser pulsing adjustment...
Страница 75: ...75 Overview XPS actuator replacement Calibrating the XPS actuator 723 0018 02 F70 XPS actuator 14...
Страница 79: ...79 Image 15 1 723 0018 02 F70 Power Supply Unit PSU 15...
Страница 83: ...83 723 0018 02 F70 Troubleshooting 16...
Страница 102: ...723 0018 02 F70 102 Troubleshooting...
Страница 104: ...723 0018 02 F70 104 Image 17 1 Assembly hierarchy...
Страница 113: ...723 0018 02 F70 113 Image 17 23 Assembly hierarchy...
Страница 114: ...723 0018 02 F70 114 Assembly hierarchy...
Страница 115: ...115 723 0018 02 F70 Scheduled operations 18...
Страница 164: ...723 0018 02 F70 164 Image 22 14 Lens shift assembly...
Страница 165: ...165 723 0018 02 F70 Prism Housing 23...
Страница 167: ...723 0018 02 F70 167 Image 23 5 Prism Housing...