manualshive.com logo in svg
background image

RGBHV Monitor Out

DVI Monitor Out

Use the 

Monitor Output 

Menu 

to set resolution and 

video source.  Both outputs 

show the same video.  

Expansion Lock Out

For external stacking 

configurations, provides 

sync and communications 

to additional DX-700s.

System Module

Output Modules

Input Module

EXP OUT

D

V

I / E

X

P I
N

RGB

H

V

1

 -H

D

/S

D

I -2

Y /
 C
O

MP

C /
 Pb

Pr

Latches

Used for precise insertion and 

removal.  See the “Module 

Insertion and Removal” section.

Expansion Out

Connects input modules for 

external and cross-bank 

stacking configurations only.

RGBHV Input

Accepts RGBHV inputs up to 

QXGA (2048 x 1536), with a 

max. 240 MHz pixel clock.

HD / SDI Input

Accepts: 

•  2 x SDI
•  2 x HD-SDI
•  1 x SDI and 1 x HD-SDI
•  1 x Dual HD-SDI

DX-700 Input Modules provide the system’s input, 
scaling, and mixing functions. Within each module, the 
input source is selected from among the various input 
connectors and scaled to the required size and position 
in the final display. 

Component Input

Accepts Composite, S-Video 

and Component.  See the 

“Format Connection Table.”

DVI / Expansion Input

Accepts single or dual DVI 

inputs, with resolutions up to 

QXGA (2048 x 1536) with a 

max. 240 MHz pixel clock.

Each module provides three outputs, which can drive one 
(or more) attached displays from any portion of a selected 
source image.

LED

 OU

T 1

LE
D O

U

T 2

LED

 OU

T 3

LED O

U

T 1

LED

 OU

T 2

LED

 OU

T 3

LED Outputs

Three DVI-I type 

connectors are 

provided for DVI 

outputs.

LED Outputs

Three HDMI-type 

connectors are 

provided for NNI 

outputs.

WARNING

Output Module connectors use proprietary 

signals and pinouts. Do not connect the 

outputs to anything other than the inputs of 

Barco LED tiles.

• Use the 

Setup Wizard

 to configure outputs and groups.

• Use the 

Input Wizard

 to configure inputs.

• Use the 

Input Management Menu

 to fine tune inputs.

DI
AGNO

STIC

ETHER

N

ET

DM

X THR

U

DM

X I
N

V I
N


/ C
S

 I

N

LOCK

MO

N

IT

O

R

GEN

L

OCK

EX
P

The System module provides connections for Ethernet, synchronization 
(genlock), monitoring, DMX and diagnostics.

Under the 

DX-700 Management Menu

:

• Use the 

Ethernet Menu

 to configure Ethernet parameters.

• Use the 

Monitor Setup Menu

 to set monitor output parameters, test patterns, and 

the monitor’s video source.

• Use the 

Genlock Menu 

to set the master sync source, and individual bank 

genlock sources.

Genlock Inputs

Single: connect 
composite sync or 
black burst to 

H/CS IN

.

Separate: connect H 
and V sync to 

H/CS IN 

and 

V IN

DMX Control

Currently not implemented.

Ethernet

100BaseT connection for 

Director Toolset 

communications.  Use the 

Ethernet Menu

 to set 

parameters.  

Diagnostic Port

For factory and technical 

support use only.  

DVI Output Module

Runs legacy LEDs.  Each 

output is limited to 

800 x 600 pixels.

NNI Output Module

Runs next generation LEDs.  

Each output is limited to 

1024 x 768 pixels.

Отзывы: