AC Power connections
5 - 3
5976418 BARON 908 04122001
Start up in operational mode
The projector can start up with the selected source or
the projector can start up with a warm up cycle message (menu 1).
PROJECTOR WARM UP
A FULL WHITE PATTERN WILL BE
GENERATED FOR x MIN.
FOR IMMEDIATE USE OF THE
PROJCTOR, PRESS <EXIT>
WARNING : SKIPPING THIS
PROCEDURE CAN REDUCE THE
INITIAL PICTURE QUALITY OF THE
PROJECTED IMAGE;
YOU CAN ADJUST THE IMAGE
DIMENSTIONS WITH THE ARROW
KEYS TO AVOID SCANNING ON
THE EDGES OF THE CRT'S;
THIS OPTION CAN BE DISABLED IN
THE SERVICE MENU
with <ENTER>
<EXIT> to return
menu 1
When this warm up cycle message appears on the screen, the menu offers the possibility to start with a x minutes taking warm up
period (press
ENTER
) or to skip this cycle (press
EXIT
). The x minutes and the horizontal frequency can be programmed in the 'Service
mode' under the item 'Projector Set Up'.
Note : This warm up period is built in so that the projector can reach its maximum specifications.
When starting this warm up period, a full white image is shifted on the CRT faceplate to avoid a burn in.
Every 30 seconds a text box will be displayed in another place on the screen with the remaining time to go.
The image dimensions can be adjusted with the cursor keys to avoid scanning on the edges of the CRT's.
To interrupt the warm up period, handle as follow:
1 Press
EXIT
, the warm up menu will be redisplayed with the remaining time indication.
2 Press
EXIT
again to quit the warm up cycle and to display the source.
Start up in stand by mode
The projector starts up in stand by.
Press a numeric key corresponding to the desired source or press STBY key.
The projector displays the selected source or the warm up cycle message.
When this warm up message appears on the screen, handle as described in 'Start up in Operational Mode'.
Stationary image warning
Do not display a stationary image with full brightness and contrast for longer than 20 min., otherwise you risk to damage the CRT's.
Содержание BARON 908
Страница 1: ...BARON 908 R9040060 R9040069 INSTALLATION MANUAL ...
Страница 2: ......
Страница 8: ...Table of contents 0 4 5976418 BARON 908 04122001 ...
Страница 16: ...Packing and dimensions 2 4 5976418 BARON 908 04122001 ...
Страница 26: ...ACPowerconnections 5 4 5976418 BARON 908 04122001 ...
Страница 34: ...Sourceconnections 6 8 5976418 BARON 908 04122001 ...
Страница 48: ...i 2 Index 5976418 BARON 908 04122001 ...
Страница 49: ......
Страница 50: ......