7. Service Mode
How to Initialize Gray level Definition?
1. Push the cursor key
↑
or
↓
to highlight
Initialize.
2. Press
ENTER
reset the Gray level Definition settings to 0.
3. Press
EXIT
to return to the
Service
Mode menu.
GRAY LEVEL DEFINITION
ADJUST
ACTIVE [OFF]
INITIALIZE
Select with
↑
or
↓
<ENTER> to toggle/select
<EXIT> to return
Menu 7-51
7.16 Purity
What is done?
This allows the user to check the gradual transition between the different color levels (=Purity).
These color levels are generated by the projector.
How to adjust Purity?
1. Push the cursor key
↑
or
↓
to highlight
Purity.
2. Press
ENTER
to select.
The Purity menu will be displayed.
3. Use the cursor keys to select the desired color (Red, Green, Blue or White) and adjustment arrow (Min, –1, +1, Max).
See image 7-11.
4. Press
ENTER
to adjust the level of the selected color (Range: 0 to 255).
The color levels will be displayed within the
Purity Adjustment
menu. (image 7-12)
5. Press
EXIT
to return to the
Service Mode
menu.
SERVICE
UNIFORMITY
ELECTRONIC CONVERGENCE
DYNACOLOR
GRAY LEVEL DEFINITION
PURITY
DISPLAY BLANKING
PANEL ADJUSTMENT
PRESET INPUT BALANCE
MORE...
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 7-52
R5976420 BARCOREALITY SIM 6 ULTRA 14052003
135
Содержание BarcoReality SIM6 Ultra R9040150
Страница 1: ...SIMULATION PRODUCTS BARCOREALITY SIM 6 ULTRA R9040150 R9040151 OWNER S MANUAL 14052003 R5976420 03...
Страница 4: ......
Страница 8: ...Table of contents 4 R5976420 BARCOREALITY SIM 6 ULTRA 14052003...
Страница 150: ...C Cleaning the Dustfilter 146 R5976420 BARCOREALITY SIM 6 ULTRA 14052003...
Страница 154: ...Index 150 R5976420 BARCOREALITY SIM 6 ULTRA 14052003...