background image

2-3

Installation Mode

5975129 BARCODATA 3300 TCR

P

LUS

 121098

Green focusing

a. Insure all convergence screws are adjusted to a length of about 33

mm (1.3") between the two plates.

b. Adjust the projection lens until optimal focus for point 1 is obtained.

c. Turn screw 2 for optimal focus of  the corresponding green line 2

on the screen.

d. This alignment influences the other, so repeat if necessary steps

b. and c. until points 1 and 2 are focused.

e. Turn screw 3 for optimal focus of the corresponding green line 3 on

the screen.

f. Repeat if necessary the steps b. to e. until the complet screen is

focused.

g. Secure the projection lens by turning the fastener ring clockwise.

Green position

a. If necessary turn screw 5 until the two horizontal lines 5 on the

screen are on one horizontal line.

When the green pattern is correctly focused, press 

EXIT

 to return to

the 

Test pattern

 menu.

Blue on green convergence.

Push the control disc up or down to hightlight 

Blue on green

 and press

ENTER

 to display the Blue on green test pattern.

The longest lines are the blue lines.  These lines must be converged

with the green lines.

The drawn screws and numbers are displayed in blue.

Follow next steps :

Blue focusing

a. Insure all convergence screws are adjusted to a length of about 33

mm (1.3") between the two plates.

b. Turn screw 1 for optimal focus of the corresponding point 1 on the

screen.

c. Turn screw 2 for optimal focus of the corresponding point 2 on the

screen.

d. Due to interaction, it may be necessary to repeat step b. and c. until

point 1 and 2 are focused.

e. Turn screw 3 for optimal focus of the corresponding point 3 on the

screen.

f. Due to interaction, it may be necessary to repeat steps b. to d. until

point 1, 2 and 3 are correctly focused.

Select with        or

then <ENTER>

<EXIT> to return.

CONVERGENCE

GREEN

BLUE ON GREEN

RED ON GREEN

HATCH

Blue position

g. Turn screw 4 until the red horizontal line coincide with the green

horizontal line in point 4 on the screen.

h. Turn screw 5 until both horizontal lines marked with 5 are on one

horizontal line.

i. Repeat step g. and h. until the horizontal lines are converged.

j. Adjust screw 6 for optimal convergence of the vertical lines.

k. Repeat step i. and j. until a optimal convergence in horizontal and

vertical direction is obtained.

Содержание BarcoData 3300

Страница 1: ...INSTALLATION MANUAL R9001450 DATA 3300 TCRPLUS ...

Страница 2: ...BARCO PROJECTION SYSTEMS INSTALLATION MANUAL Date 121097 Art No R5975129 R9001450 DATA 3300 TCRPLUS ...

Страница 3: ...equipment does cause interference to radio or television reception the user may try to correct the interference by one or more of the following measures Re orientation of the receiving antenna for the radio or television Relocate the equipment with respect to the receiver Plug the equipment into a different outlet so that the equipment and receiver are on different branch circuits Fasten cables co...

Страница 4: ...121098 i TABLE OF CONTENTS TABLEOFCONTENTS i 1 INSTALLATIONMODE 1 1 Starting up the Installation Mode 1 1 Configuration 1 1 Internal Patterns 1 1 How to use the built in adjustable lensholder 1 2 HARDWARESETUP 2 1 How to activate the password function 2 1 ...

Страница 5: ...ue screen when no source is connected to the projector Only the items used during the physical installation will be explained hereafter The other items are explained in the owners manual Select with or then ENTER EXIT to return INTERNAL PATTERNS OUTLINE COLOR BARS MULTIBURST CHECKER BOARD PURITY PAGE CHAR ALPHA NUMERIC CHAR GRAY BARS Select with or then ENTER EXIT to return Configuration Highlight...

Страница 6: ... to a computer in chapter Connections The three mounting parts for the LCD s two are shown on the drawing below are located on the black metal cover The screws are indicated from 1 to 6 for each color To adjust the convergence there are test patterns provided in the service menu Push the control stick forward or backward to hightlight Convergence and press ENTER to display the Convergence menu Sta...

Страница 7: ...ngest lines are the blue lines These lines must be converged with the green lines The drawn screws and numbers are displayed in blue Follow next steps Blue focusing a Insure all convergence screws are adjusted to a length of about 33 mm 1 3 between the two plates b Turn screw 1 for optimal focus of the corresponding point 1 on the screen c Turn screw 2 for optimal focus of the corresponding point ...

Страница 8: ...ensholder With the lensholder it is possible to shift the displayed image up or down on the screen without moving the projector from its normal positioin and without any geometric picture distortion This built in feature is particularly useful for use in dual projector configurations or for applications when the projector cannot be installed in its standard position Features Vertical and horizonta...

Страница 9: ... Use the hand screw Shift the image up or down until the correct vertical position of the image is obtained Turn clockwise to shift the image up turn counter clockwise to shift down Use the hand screw Midposition of the adjustable lensholder If the top cover is opened the lensholder indication line has to match with the center of the hole in the plate behind the lensholder If the top cover is clos...

Страница 10: ...ower down the projector and unplug the power cord from the wall outlet Turn both lock screws with a screwdriver or coin counter clockwise Lift up and pivot the top cover Attention the cover is not secured with an incorporated support When opening turn it over slowly The processor module with the DIP switches is located on the front side Loosen the locking screws Open the top cover When DIP switch ...

Отзывы: