3. Getting started
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 06 – February-2005
___________________________________________________________________
3-25
3.2.13
CPU board
The CPU board controls amongst other the remote power on/off mechanism between the O
MNI
B
US
devices and
its host and the transmission of a genlock signal.
Connectors
On the CPU board there are two RJ-45 connectors for connecting the remote power on/off cables.
Do not remove the sheet metal plate. The connector behind is reserved for diagnostic
purposes.
Figure 3-33
connectors of CPU board
Connecting order remote power on/off
Each A
RGUS
O
MNI
B
US
should be connected to its host for the remote power on/off mechanism. Therefore the
remote power on/off
connector [16] on the back of the host (A
RGUS
P
ROCESSOR
or rendering processor) must be
connected with the
remote power on/off in
connector of the CPU board of the O
MNI
B
US
. Multiple O
MNI
B
US
de-
vices are connected in a daisy chain to their host by connecting the
remote power on/off out
connector of the
first O
MNI
B
US
to the
remote power on/off in
connector of the next O
MNI
B
US
and so on. The
remote power
on/off out
connector of the last O
MNI
B
US
remains unconnected.
Figure 3-34
cabling for remote power on/off
Do not mix up the connetors for remote power on/off with the mechanically identical
connectors of the network adapters!
Mixing the connectores will cause damage to the system.