ACS-2048 • User’s Guide
65
4. Operation
Using the Main Menu
aá~ÖåçëíáÅë
From the
System Menu
, select
Diagnostics
to display the
Diagnostics Menu
:
Figure 4-39.
Diagnostics Menu
If you suspect a problem with the ACS-2048, press
SEL
to run a series of internal
diagnostic tests. The menu will report back “
PASS
” or “
FAIL
.”
p~îÉ=póëíÉã=`çåÑáÖ
From the
System Menu
, select
Save Config
to save all current “system” settings so that
they may be restored at power up. A message is briefly shown, after which the ACS-2048
returns to the
System Menu
.
Figure 4-40.
Saving System Configuration Message
Please note the following important points regarding the system configuration file:
•
When you perform the
Save Config
function, all configuration parameters from
the
System Menu
are saved in non-volatile memory. If you
do not
perform the
function, data will not be restored upon the next system power up sequence.
•
This command also saves the currently selected
input
channel as the default
selection upon power up.
•
If you
do not
perform the
Save System State
function, data will not be restored
upon the next system power up sequence.
D I A G N O S T I C S
> S E L = S t a r t T e s t s
Note
If the menu report “
FAIL
,” please contact Barco Customer
Service. They will assist you with troubleshooting.
S a v i n g S y s t e m C o n f i g . . .
Note
If you want the ACS-2048 to always power up and acquire an
input other than input 1, perform the
Save System State
command while the desired input is selected.