3-1
Location and Functions of Control
5975119A BARCODATA 3300DLC 121098
3
56,1
56287 &2003257 $8',2287 &75/
Remote
: Remote input for wired remote control.
Loudspeaker
: for use in small areas only.
IR-Acknowledged :
IR signals are recognized (green
led).
IR-Received :
IR signals are received but not recognized
by the projector (red led).
IR receiver
: Receiver for control signals transmitted from
the RCU.
Diagnostics code :
a) Source number
b) Error code : A two digits error code is displayed when
something goes wrong inside the projector.
Projector mode indication
: Indicates the status of the
projector.
No lighting up : Power switch is not pressed.
Red lighting up : Power switch is pressed, projector in
stand by mode.
Green lighting up : Projector in operational mode.
1
Power switch
:
'1' = on, '0' = off
Power input
: Autoranging from 90 to 250 Vac.
Audio input
for Video signals only.
3
2
4
5
6
7
8
9
10
11
12
13
14
15
LOCATION AND FUNCTION OF CONTROLS
Front panel terminology
RS232 IN
: To allow communication with external compu-
ter, e.g. IBM PC or compatible, Macintosh ...
RS232 OUT
: Used to connect to next projector, RS232IN
plug (communication link for PC or MAC to the next
projector).
Communication port
: Allows communication with the
800 peripherals.
Audio output
.
Input slots :
Slot 1 : Serial SDI input.
Slot 2 and 3 : modular input facilities. 2 input modules can
be inserted. The sequence of insertion has no impor-
tance.
The following modules can be inserted :
- Video, S-Video (PAL, SECAM, NTSC) input
- RGBS/RGsB analog input
- RGB3S/RG3sB input
- Component Video input
- 5 cable input