USE AND CARE INSTRUCTIONS
11
If growing bubbles appear do not use or move
the LP Gas tank. Contact an LP Gas Supplier
or your fire department!
WARNING
!
!
Secure a 20lb LP Gas Tank to Gas Side Burner
Note: You can only use 20lb LP Gas Tank with this
Side Burner.
NOTE:
When using Propane (LP), EXTREME CAUTION
should be used to provide ample ventilation of vapor
from the enclosure. LP Gas vapor is heavier than air
and SERIOUS INJURY from a DANGEROUS EXPLO-
SION could occur if LP Gas is allowed to accumulate
in an enclosure and then ignited. Both the Barbeque
enclosure and LP cylinder enclosure require venting that
must be provided at the floor level of the enclosure to
allow any leaking LP Gas vapor to escape (see Fig. 6).
NOTE:
When installing a barbeque equipped for liquid
propane (LP) in an island, the LP tank must be in a
separate enclosure that is completely isolated from the
barbeque. It must be cross-ventilated in accordance with
local codes. The LP tank MUST NEVER be installed
directly under the barbeque.
NOTE
: The total of the upper ventilation openings must
be a minimum of 20 sq. inches. The total of the lower
ventilation openings must be a minimum of 10 sq.
inches. Upper and lower ventilation openings MUST BE
PROVIDED on both sides of built-in construction. The
top of the upper ventilations openings must be located
within 5" from the top of the island. The bottom of the
lower ventilation openings must be at least 1" or less
from the floor of the island. The top of the lower
ventilation openings cannot be more than 5" from the
floor of the island. Every ventilation opening must have
a minimum of 1/8" (See Fig. 4 on page 9). Contact a
Grand Hall associate for more details.
Note: The built-in appliance for use with a remote self-
contained LP Gas supply system must use rigid pipe,
semi-rigid tubing or a connector complying with the
Standard for Connections for Gas Appliance,
ANSI
Z21.24/CSA 6.10
Fig. 6
NOTE about LP Gas Tank Exchange Programs
How to Leak Test your LP Gas Tank
All leak tests must be repeated each time your LP Gas
tank is exchanged or refilled.
When checking for gas leaks do not smoke.
Do not use an open flame to check for gas leaks.
Your side burner must be leak tested outdoors in a well-
ventilated area, away from ignition sources such as gas
fired or electrical appliances. During the leak test, keep
your side burner away from open flames or sparks.
Do not use household cleaning agents. Damage to gas
assembly components can result.
For your safety:
Leak test new and exchanged LP Gas tanks BEFORE
connecting one to your side burner.
Always keep new and exchanged LP Gas tanks in an up-
right position during use, transit or storage.
Use a clean paintbrush and a 50/50 mild soap and
water solution.
Brush soapy solution onto LP Gas tank in the areas
indicated by the arrows. See diagram.
If growing bubbles appear do not use or move the
LP Gas tank. Call an LP Gas Supplier or your Fire
Department.
Many retailers that sell gas appliances offer you the op-
tion of replacing your empty LP Gas tank through an ex-
change service. Use only those reputable exchange com-
panies that inspect, precision fill, test, and certify their
tanks. Exchange your tank only for an OPD safety feature-
equipped tank as described in the LP Gas tank section of
this Guide.
Ÿ
Ÿ
Ÿ
Non-Combustible
Construction, such as
stone, marble, cement
Air Vents
Partition Panel
Stainless Steel Tube
(Refer to the Note
below).
5/8" UNF