17
EVO 80-65
Installation instructions
2.2.4 Combustion air supply / Chimney
Every appliance needs its own chimney. Multiple connections to one main chimney is
not permitted. Ensure that any existing chimney is completely air-tight and in good
condition. It must be suitable to accommodate the appliance in question. Make sure
your chimney has a proper cap to prevent rain getting in and birds nesting on it.
The draught in your chimney determines how your appliance will burn. The recommen-
ded draught is approx. 15 Pa (0.15 mbar). Your chimney should be at least 4 metres tall
from the point at which the chimney connects to the appliance.
Chimneys which are well-insulated measuring in excess of 8 metres can develop a
signifi cant draught if the appliance is raging. We therefore advise you to fi t a chimney
damper or draught diverter between appliance and the chimney.
Ensure that any existing chimney is completely air-tight and in good condition. The
diameter of the entire chimney, including the chimney pot on the roof must have a
diameter at least equal to the diameter of the fl ue gas outlet of the appliance. See
Chapter 7.
If there is no suitable chimney immediately available, we advise you to use double-
walled insulated stainless steel pipe sections. A chimney must be compliant with the
prevailing building regulations. Have a specialist carry out the building. When purchasing
such pipe sections, we advise you to fi nd out whether some form of casing of the pipes
is required.
A few points for your attention:
• chimneys must be free-standing, i.e. they must not rest on the appliance itself.
• all connections between the appliance and the chimney must be properly insulated.
• fl ammable material must be kept clear (outside the casing/insulation zone) of all
through-feeds in the fl oor or wall (remember the roof decking).
Do not make any horizontal connections. Deposits and soot will collect here (unless it is
a short horizontal connection directly behind the built-in fi re).
The chimney calculation, as in Germany, is made according to DIN 4705 parts 1 and 2
with each of the following measured values:
- mass fl ow of the fl ue gasses
: 13 g/s
- temperature of the fl ue outlet on the fi re : 234°C
- chimney draught
: 0.12 mbar
- nominal power output
: 14 kW
Содержание EVO 80-65
Страница 2: ......
Страница 4: ...4 EVO 80 65 Installation instructions...
Страница 5: ...5 EVO 80 65 Installation instructions...
Страница 6: ...6 EVO 80 65 Installation instructions...
Страница 33: ...33 EVO 80 65 Installation instructions 5 DIMENSIONS 5 1 EVO 80 65 with 80 mm frame...
Страница 34: ...34 EVO 80 65 Installation instructions 5 2 EVO 80 65 with 80 mm frame with natural stone plateau...
Страница 40: ...01 151013 334801 Your Barbas dealer...