background image

ECscan20/30/40 

 

Specifications 

 

Conductivity 

Model 

ECscan20 

ECscan30 

ECscan40 

Range 

0 to 20.00, 200.0, 2000

 

μ

S/cm, 20.00

 

mS/cm 

Resolution 

0.01, 0.1, 1 

Accuracy 

± 1% F.S. 

Calibration Point 

1, 2 or 3 points 

Calibration Solution 

84

 

μ

S/cm, 1413

 

μ

S/cm, 12.88

 

mS/cm 

TDS 

Range 

--- 

0 to 10.00, 100.0, 1000

 

ppm, 20.00

 

ppt 

Resolution 

--- 

0.01, 0.1, 1 

Accuracy 

--- 

± 1% F.S. 

TDS Factor 

--- 

0.1 to 1.0 

Salinity 

Range 

--- 

0.00 to 10.00

 

ppt 

Resolution 

--- 

0.01

 

ppt 

Accuracy 

--- 

± 1% F.S. 

Temperature 

Range 

0 to 60° C (32 to 140° F) 

Resolution 

0.1° C (0.1° F) 

Accuracy 

± 1° C (± 1.8° F) 

Calibration Point 

1 point, reading ± 10° C 

Other Specifications 

Temperature Compensation 

0 to 60° C (32 to 140° F), automatic 

Temperature Coefficient 

2%/° C 

Reference Temperature 

25° C 

Operating Temperature 

0 to 50° C (32 to 122° F) 

Storage Temperature 

-5 to 60° C (23 to 140° F) 

Relative Humidity 

< 80% (non-condensing) 

Display 

Dual-line LCD, 21

 

×

 

21

 

mm (0.82

 

×

 

0.82") 

Power Requirements 

2

 

×

 

1.5V AAA alkaline batteries 

Auto-Off 

8 minutes after last key pressed 

Dimensions 

185

 

(L)

 

×

 

40

 

(Dia.)

 

mm (7.28

 

×

 

1.57") 

Weight 

100

 

g (3.5

 

oz.) 

 

 

Disposal 

This tester 

is required to comply with the European Union’s Waste

 Electrical and Electronic Equipment (WEEE) 

Directive 2002/96/EC and may not be disposed of in domestic waste. Please dispose of this product in   
accordance with local regulations at the collecting point specified for

 

electrical and electronic equipment. 

 

Warranty 

The warranty period for tester is 1 year from the date of shipment.

 

Above warranty does not cover the standard 

solution.

 

Out of warranty products will be repaired on a charged basis. The warranty on your meter shall not 

apply to defects resulting from: 

•    Improper or inadequate maintenance 

by customer. 

•    Unauthorized modification or misuse.

 

•    Operation outside of the environment specifications of the products.

 

For more information, please contact the supplier. 

Содержание ECscan20

Страница 1: ...ECscan20 30 40 Pocket Conductivity Tester Instruction Manual Bante Instruments Inc...

Страница 2: ...urement Exit the calibration setting and return to the measurement mode Start calibration Press and hold key to enter the setup menu Select an option Confirm the calibration setting or displayed optio...

Страница 3: ...Disable When the option is enabled the tester will automatically switch off if no key is pressed within 8 minutes Enable Enable Disable Reset the tester to factory default settings Enable Disable Disa...

Страница 4: ...ster enters the calibration mode the display shows CAL 1 1 2 Rinse the electrode with deionized water and place into the standard solution Stir tester gently to remove air bubbles trapped in the slot...

Страница 5: ...he Enter the tester will show Conductivity TDS Salinity icon and switch to the corresponding measurement mode Measuring the Sample Rinse the electrode with deionized water Place the electrode into the...

Страница 6: ...precisely weighed NaCl or KCL reagent Actual Conductivity The meter measured conductivity value For example dissolve 64 grams of KCl reagent in 1 litre deionized water If measured conductivity value i...

Страница 7: ...ndensing Display Dual line LCD 21 21mm 0 82 0 82 Power Requirements 2 1 5V AAA alkaline batteries Auto Off 8 minutes after last key pressed Dimensions 185 L 40 Dia mm 7 28 1 57 Weight 100g 3 5oz Dispo...

Страница 8: ...ce 4715 Castlewood St Sugar land TX 77479 USA Tel 1 346 762 7358 E mail banteinstruments yahoo com Factory A10 No 2066 Laifang Rd Shanghai 201615 China Tel 86 21 6404 1598 E mail banteinstrument hotma...

Отзывы: