June 23, 2023
T30RW R-GAGE Washdown Radar Sensor Instruction Manual
27
Continued from page 26
C.
The Raw Measurement change (blue lines) is greater than the Max Distance Change (red lines) so the Output
Measurement (green lines) holds its previous value while the Raw Measurement is beyond the Max Distance
Change. After the 1 second Hold Time expires, the Output Measurement and Max Distance Change thresholds
are updated based on the next Raw Measurement value.
D.
The Raw Measurement (blue lines) drops down to a value below the Max Distance Change (red lines) so the
Output Measurement (green lines) holds its value for the Hold Time. After the 1 second Hold Time expires, the
Output Measurement and Max Distance Change thresholds are updated based on the next Raw Measurement
value.