June 23, 2023
T30RW R-GAGE Washdown Radar Sensor Instruction Manual
20
The remote input wire is disabled by default. Pulse the remote input wire 10 times or use the
Banner Radar
Configuration
software to enable the feature. After enabling the remote input feature, pulse the remote input according to the
diagram and the instructions provided in this manual. Remote teach can also be performed using the button on the Pro
Converter Cable.
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by setting the remote input Low for longer than 2 seconds or by waiting for 60 seconds.