Setting
Factory Default
On Delay
0 ms
Off Delay
500 ms
Discrete 2 Tab Default Settings
Setting
Factory Default
Output Mode
Switch Point
Setpoint 1
15.0 m (49.2 ft)
Hysteresis
0.05 m (2 in)
NO/NC
Normally Open
On Delay
0 ms
Off Delay
500 ms
Using Measurement Hold Example
Measurement Hold (The hold time is set to 1 second)
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
D
is
ta
n
c
e (m)
Time (s)
A
B
C
1 sec
D
Raw Measurement
Output Measurement
Maximum Distance Decrease
Maximum Distance Increase
1 sec
<1 sec
0
1
2
3
4
5
6
7
8
9
10
A.
The Max Distance Change threshold (red lines) adapts based on the previous Raw Measurement sample (blue
lines) as long as that sample was within the previous thresholds.
B.
The temporary distance spike in the Raw Measurement (blue lines) is filtered out because the distance increase
was outside of the Max Distance Change (red lines). The Output Measurement (green lines) will hold its last
measurement.
Continued on page 27
© Banner Engineering Corp.
Содержание T30RW
Страница 3: ...3 Banner Engineering Corp Software Copyright Notice 41 Banner Engineering Corp Limited Warranty 41...
Страница 4: ...Blank page 4...
Страница 8: ...Blank page 8...
Страница 18: ...Blank page 18...
Страница 28: ...Blank page 28...
Страница 34: ...Blank page 34...
Страница 36: ...Blank page 36...
Страница 40: ...Blank page 40...
Страница 43: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...