background image

ESLP1-30/60-NW

E-Stop Legend, Plastic

Blank

60 mm diameter (OD)

30 mm hole

ESLP1-30/60

E-Stop Legend, Plastic

"Emergency Stop”

60 mm diameter (OD)

30 mm hole

ESL-41/60 (1 each)
ESL-41/60-10 (10 each)

E-Stop Legend, Label

"Emergency Stop”

60 mm diameter (OD)

41 mm hole for

application around

SSA-EB1P…

ESL-41/60-ENES (1 each)
ESL-41/60-ENES-10 (10 each)

E-Stop Legend, Label

"Emergency Stop -

Parada de Emergencia”

60 mm diameter (OD)

41 mm hole for

application around

SSA-EB1P…

ESL-44/70 (1 each)
ESL-44/70-10 (10 each)

E-Stop Legend, Label

"Emergency Stop”

70 mm diameter (OD)

44 mm hole for

application around

SSA-EB1M…

EM

ER

GE

NC

Y  

STO

P

EM

ERGENCY  STO

P

w

w

w

.b

an

n

er

en

g

in

ee

rin

g.

co

m

ESC-1-YW

Emergency stop cover

72 mm wide; 30 mm center hole

For use on standard (non-lockable)
40mm models

U.S. Application Standards

ANSI B11.0 Safety of Machinery, General Requirements, and Risk Assessment
ANSI B11.19 Performance Criteria for Safeguarding
NFPA 79 Electrical Standard for Industrial Machinery

International/European Standards

EN ISO 12100 Safety of Machinery – General Principles for Design — Risk Assessment and Risk Reduction
ISO 13850 (EN 418) Emergency Stop Devices, Functional Aspects – Principles for Design
IEC 62061 Functional Safety of Safety-Related Electrical, Electronic and Programmable Control Systems
EN ISO 13849-1 Safety-Related Parts of Control Systems
IEC/EN 60204-1 Electrical Equipment of Machines Part 1: General Requirements
EN 60947-1 Low Voltage Switchgear – General Rules
EN 60947-5-1 Low Voltage Switchgear – Electromechanical Control Circuit Devices
EN 60947-5-5 Low Voltage Switchgear – Electrical Emergency Stop Device with Mechanical Latching Function

EU/UK Declaration of Conformity (DoC)

Banner Engineering Corp. herewith declares that these products are in conformity with the provisions of the listed directives,

regulations, and all essential health and safety requirements have been met. For the complete DoC, please go to 

www.bannerengineering.com

.

Product

Directive

SSA-EB1P and PL Emergency Stop Push Button

EU: Machinery Directive 2006/42/EC; Low Voltage Directive

2014/35/EU
UK: Machinery (Safety) Regulations 2008

Representative in EU: Spiridon Lachanidis, Managing Director, 

Banner Engineering Europe

 Park Lane, Culliganlaan 2F bus 3,

1831 Diegem, BELGIUM

SSA-EB Series Emergency Stop Push Button

 

 

P/N 194992 Rev. D

www.bannerengineering.com - Tel: + 1 888 373 6767

11

Содержание SSA-EB Series

Страница 1: ...quirements of the isolation of hazardous energy see OSHA 29CFR1910 147 ANSI Z244 1 CSA Z460 ISO 14118 The locking feature can be used to provide supervisory personal control and provide an additional...

Страница 2: ...es WARNING Connect two or more devices to the same safety module controller in series Connecting devices in parallel defeats the switch contact monitoring ability of the module and creates an unsafe c...

Страница 3: ...hten the M30 jam nut using wrench SSA EB1 LRW or SSA EB1 LRTW to a maximum torque of 2 5 N m 1 8 ft lbs Note The allowable panel thickness is 1 mm to 5 mm for SSA EB1P and 1 mm to 6 mm for SSA EB1M Ba...

Страница 4: ...PL1 11 SSA EB1ML1P 11 1 normally closed NC 1 normally open NO 11 12 X2 23 24 X1 LED24V SSA EB1P 13 SSA EB1MP 13 3 normally closed NC 1 normally open NO 22 11 12 21 41 42 34 33 SSA EB1PL1 13 SSA EB1ML1...

Страница 5: ...Cover Install the SSA EB1 TC Terminal Cover 1 Align the TOP mark on the SSA EB1 TC terminal cover with the TOP mark on the contact block 2 Place the two projections on the bottom of the contact block...

Страница 6: ...hould test each safety point for proper machine shutdown response A Designated Person should check the safety point for proper operation physical damage button looseness and excessive environmental co...

Страница 7: ...mA Output Configuration See Installation and Maintenance on page 2 Mechanical Life 250 000 operations Terminals M3 screw terminal terminal cover included Recommended Torque 0 6 to 1 0 N m 5 3 to 8 8 i...

Страница 8: ...0947 5 1 See Electrical Rating above for specific model and UL CE maximum ratings Required Overcurrent Protection WARNING Electrical connections must be made by qualified personnel in accordance with...

Страница 9: ...rol units of different sizes and styles determine the values according to the dimensions operation and wiring convenience For padlock style lockable emergency stop push buttons determine the values ac...

Страница 10: ...d contact blocks including LED indicators are only available as complete units and are not sold separately SSA EB1 FSTC IP20 Finger safe terminal cover SSA EB1 TC Standard terminal cover supplied SSA...

Страница 11: ...Assessment and Risk Reduction ISO 13850 EN 418 Emergency Stop Devices Functional Aspects Principles for Design IEC 62061 Functional Safety of Safety Related Electrical Electronic and Programmable Cont...

Страница 12: ...RA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRAC...

Отзывы: