Specifications

Button/Locking Collar

Polyamide/Aluminum

Insulation Resistance

100 MΩ minimum (500 V DC megger)

Rated Current (Ith)

5A

Impulse Withstand Voltage

2.5 kV

Pollution Degree

3

Overvoltage Category

II

Vibration Resistance

Operating extremes: 10 Hz to 500 Hz, amplitude 0.35 mm acceleration 50

m/s

2

Shock Resistance

Operating extremes: 150 m/s

2

 (15G)

Direct Opening

Force: 80 N Minimum

Travel: 4.0 mm Minimum

Button Travel

4.5 mm Maximum

Contact Resistance

50 mOhm maximum (initial value)

Operating Frequency

900 operations/hour

LED Color

Red (The LED is built into the contact block and cannot be replaced)

LED Voltage/Maximum Current

24 V AC/DC ±10%, 15 mA

Total Weight of Padlock and Hasp (SSA-EB1M..-.. only)

1500 g (3.3 lb) maximum

Rated Insulation Voltage (Ui)

250 V

Operating Humidity

45% to 85% RH (no condensation)

Contact Material/Bounce

4

Gold plated silver / 20 ms

Electrical Rating

Minimum load: 1 mA at 5 V AC/DC

Maximum Rated Load:

 See table

UL Applications: 1.5 A at 250 V AC, 1 A at 30 V DC (pilot duty)

CE Applications: AC-15: 1.5 A at 250 V AC, DC-13: 1 A at 30 V DC

Electrical Life

100,000 operations minimum, 250,000 operations minimum at 24 V

AC/DC, 100 mA

Output Configuration

See 

Installation and Maintenance 

on page 2

Mechanical Life

250,000 operations

Terminals

M3 screw terminal (terminal cover included)

Recommended Torque: 0.6 to 1.0 N·m (5.3 to 8.8 in-lbf)

Allowable Wire: 0.75 to 1.25 mm

2

 (18 to 16 AWG)

B10d

100,000 (based on ISO13849-1(2006))

Operating Temperature

Non-illuminated: –25 °C to +60 °C (–13 °F to +140 °F)

Illuminated: –25 °C to +55 °C (–13 °F to +131 °F)

Environmental Rating

Actuator: IP65 (IEC 60529)

Terminal: IP20 with SSA-EB1-FSTC installed

Standards

Design and Compliance

: EN/IEC 60497-5-1, EN/IEC 60947-5-5, UL 508, CSA

C22.2 No.14

Application and Other Applicable Standards (not all inclusive)

: ISO 13850,

ANSI B11.19, IEC 60204-1, NFPA79

Date code format (U.S. Standard Format)

YYWWX:

 2-digit year, 2-digit week, "X” internal code

Certifications

S

Banner Engineering Europe

 Park Lane,

Culliganlaan 2F bus 3, 1831 Diegem,

BELGIUM

Turck Banner LTD

 Blenheim House,

Blenheim Court, Wickford, Essex SS11 8YT,

Great Britain

4

When the button is reset, the normally closed contacts will chatter. When pressing the button, the normally open contacts will chatter. When designing a control circuit, take the contact chatter time
into consideration. Do not expose the switch to external shocks, otherwise the contacts will bounce.

SSA-EB Series Emergency Stop Push Button

 

 

P/N 194992 Rev. D

www.bannerengineering.com - Tel: + 1 888 373 6767

7

Содержание SSA-EB Series

Страница 1: ...quirements of the isolation of hazardous energy see OSHA 29CFR1910 147 ANSI Z244 1 CSA Z460 ISO 14118 The locking feature can be used to provide supervisory personal control and provide an additional...

Страница 2: ...es WARNING Connect two or more devices to the same safety module controller in series Connecting devices in parallel defeats the switch contact monitoring ability of the module and creates an unsafe c...

Страница 3: ...hten the M30 jam nut using wrench SSA EB1 LRW or SSA EB1 LRTW to a maximum torque of 2 5 N m 1 8 ft lbs Note The allowable panel thickness is 1 mm to 5 mm for SSA EB1P and 1 mm to 6 mm for SSA EB1M Ba...

Страница 4: ...PL1 11 SSA EB1ML1P 11 1 normally closed NC 1 normally open NO 11 12 X2 23 24 X1 LED24V SSA EB1P 13 SSA EB1MP 13 3 normally closed NC 1 normally open NO 22 11 12 21 41 42 34 33 SSA EB1PL1 13 SSA EB1ML1...

Страница 5: ...Cover Install the SSA EB1 TC Terminal Cover 1 Align the TOP mark on the SSA EB1 TC terminal cover with the TOP mark on the contact block 2 Place the two projections on the bottom of the contact block...

Страница 6: ...hould test each safety point for proper machine shutdown response A Designated Person should check the safety point for proper operation physical damage button looseness and excessive environmental co...

Страница 7: ...mA Output Configuration See Installation and Maintenance on page 2 Mechanical Life 250 000 operations Terminals M3 screw terminal terminal cover included Recommended Torque 0 6 to 1 0 N m 5 3 to 8 8 i...

Страница 8: ...0947 5 1 See Electrical Rating above for specific model and UL CE maximum ratings Required Overcurrent Protection WARNING Electrical connections must be made by qualified personnel in accordance with...

Страница 9: ...rol units of different sizes and styles determine the values according to the dimensions operation and wiring convenience For padlock style lockable emergency stop push buttons determine the values ac...

Страница 10: ...d contact blocks including LED indicators are only available as complete units and are not sold separately SSA EB1 FSTC IP20 Finger safe terminal cover SSA EB1 TC Standard terminal cover supplied SSA...

Страница 11: ...Assessment and Risk Reduction ISO 13850 EN 418 Emergency Stop Devices Functional Aspects Principles for Design IEC 62061 Functional Safety of Safety Related Electrical Electronic and Programmable Cont...

Страница 12: ...RA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRAC...

Отзывы: