12.3 Universal (Input) Safety Modules
UM-FA-xA Safety Modules provide forced-guided, mechanically-linked relay (safety) outputs for the EZ-SCREEN LS system
with a 5-pin interconnect (P5) or 8-pin interconnect (P8) when a manual reset (latch) is required by the application. See
for more information.
Model
Description
UM-FA-9A
3 normally open (N.O.) redundant-output 6 amp contacts
UM-FA-11A
2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed (N.C.) auxiliary
contact
12.4 Safety Controllers
Safety Controllers provide a fully configurable, software-based safety logic solution for monitoring safety and non-safety
devices. For additional models and XS26 expansion modules, see instruction manuals p/n
(SC22-3).
Non-Expandable Models Expandable Models
Description
SC26-2
XS26-2
26 convertible I/O and 2 Redundant Solid State Safety Outputs
SC26-2d
XS26-2d
26 convertible I/O and 2 Redundant Solid State Safety Outputs with Display
SC26-2e
XS26-2e
26 convertible I/O and 2 Redundant Solid State Safety Outputs with
Ethernet
SC26-2de
XS26-2de
26 convertible I/O and 2 Redundant Solid State Safety Outputs with Display
and Ethernet
Model
Description
SC22-3-S
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display
SC22-3-SU1
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display (includes
programming tool and USB cable)
SC22-3E-S
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display and Ethernet
SC22-3E-SU1
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display and Ethernet
(includes programming tool and USB cable)
12.5 Muting Module
Provides the muting capability for the EZ-SCREEN LS. See Banner manual
for more information and additional
cabling options.
Model
Description
MMD-TA-11B
DIN-mount Muting module
2 N.O. safety outputs (6 amps), 2 or 4 muting inputs, SSI, override input; IP20; terminal
connections
MMD-TA-12B
2 OSSD outputs, 2 or 4 muting inputs, SSI, override input; IP20; terminal connections
12.6 Interface Modules
IM-T-..A interface modules provide forced-guided, mechanically-linked relay (safety) outputs for the EZ-SCREEN LS System
with an 8-pin interconnect (with EDM function). The IM-T-..A interface module is required to be monitored by the EDM
for more information.
EZ-SCREEN
®
LS Safety Light Screen
www.bannerengineering.com - Tel: +1.763.544.3164
87