thoroughly familiar with all applicable standards, some of which are listed within the specifications. Banner Engineering

Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or effectiveness of any

information provided, or the appropriateness of the provided information for a specific application.

1.3 EU Declaration of Conformity (DoC)

Banner Engineering Corp. herewith declares that these products are in conformity with the provisions of the listed directives

and all essential health and safety requirements have been met. For the complete DoC, please go to 

www.bannerengineering.com

.

Product

Directive

SI-RF Radio Frequency Safety Switch

2006/42/EC

Representative in EU: Peter Mertens, Managing Director, Banner Engineering BV. Address: Park Lane, Culliganlaan 2F, bus

3,1831 Diegem, Belgium.

1.4 Overview

Use the SI-RF Radio Frequency Safety Switch to monitor the position of a guard to detect its movement, opening, or

removal. A "guard" can be a gate, door, cover, panel, barrier or other physical means that separates an individual from a

hazard. Safety switches will issue a signal to the machine control system to prevent or stop (halt) hazardous situations when

the guard is not in the proper position. The SI-RF Safety Switch is designed for non-locking guarding applications, unless

another means of locking is provided.
The SI-RF Safety Switch is considered a Type 4 interlocking device per ISO 14119 that are actuated by an electronic field

interacting with the coded actuator typically mounted on the guard. Different levels of coded sensors are available: low,

high, and unique.
Applications involving the use of the SI-RF Safety Switch should take into consideration the following standards:

• ISO 13849-1/2 - Safety of Machinery - Safety Related Parts of Control Systems

• ISO 12100 - Safety of Machinery - Risk Assessment and Risk Reduction

• ISO 14119 - Safety of Machinery - Interlocking Devices Associated with Guards

• ANSI B11.0 - Safety of Machinery - General Requirements and Risk Assessment

• ANSI B11.19 - Performance Criteria for Safeguarding

The SI-RF Safety Switch can be used individually or in series. A series string can consist of 1 to 32 units. The redundant

safety inputs are only used for the serial connection of sensors (for an individual unit or last in the string they get tied to +24

V dc). The redundant safety outputs can be used for serial connection of sensors or for the connection to the safety related

parts of the control system.

SI-RF Non-Contact RF Safety Switch

 

 

4

www.bannerengineering.com - Tel: + 1 888 373 6767

 

Содержание SI-RF Series

Страница 1: ...SI RF Non Contact RF Safety Switch Instruction Manual Original Instructions 208885 Rev F 31 August 2020 Banner Engineering Corp All rights reserved 208885...

Страница 2: ...ion 10 3 8 1 Protective Stop Safety Stop Circuits 10 3 8 2 Output Signal Switching Devices OSSDs and External Device Monitoring EDM 10 3 8 3 Wiring for Single PNP SI RFP 11 3 8 4 Wiring for a Single 8...

Страница 3: ...RFPT UP5 Unique 250 mm cable with an 5 pin M12 Euro style quick disconnect SI RFPT HP5 High SI RFPT LP5 Low SI RF A Actuator Actuator target for all switches SI RF A2 Low Profile Actuator target for a...

Страница 4: ...situations when the guard is not in the proper position The SI RF Safety Switch is designed for non locking guarding applications unless another means of locking is provided The SI RF Safety Switch i...

Страница 5: ...Switch for minimum 5 seconds The amber and green LED on the SI RF Safety Switch flash with flash code 6 for 1 5 seconds see Status Indicators on p 21 The new actuator code is stored temporarily 3 Dis...

Страница 6: ...anical or end of travel stop When the guard is closed the actuator is guided to the sensor When the switch on distance is reached the sensor detects the actuator code If the sensor detects an acceptab...

Страница 7: ...eset switch additional safeguarding must be provided WARNING Pass Through Hazards and Perimeter Guarding Lockout Tagout procedures per ANSI Z244 1 may be required or additional safeguarding as describ...

Страница 8: ...5 mm between the SI RF Safety Switch and actuator to ensure there is no activation within the side lobes The specified sensing distances can only be reached if the following conditions are met Do not...

Страница 9: ...e reset button when the guard is in the closed position WARNING Use of Auto or Manual Restart Failure to follow these instructions could result in serious injury or death Application of power to the B...

Страница 10: ...ty function Such a circuit can be described as a safe switching point Typically protective stop circuits are either single channel which is a series connection of at least two normally open contacts o...

Страница 11: ...safety monitoring device that monitors the status of the two SI RF Safety Switch OSSDs and is capable of providing the EDM function Examples of appropriate external safety monitoring devices include...

Страница 12: ...e 8 Conductor Sensor 24 34 14 24Vdc 24Vdc 0Vdc 0Vdc L2 V L1 V EDM SC10 23 33 13 Safety Relay Outputs 43 44 53 54 and 63 64 can be wired similarly but require a separate EDM or AVM input for monitoring...

Страница 13: ...ing the switch in series 3 8 6 Wire the Switch in Series Using the Quick Disconnect Use models SI RFS and SI RFD for this configuration When connecting units in series simplify the wiring using specia...

Страница 14: ...monitor the individual device voltages see In Series Diagnostic Information on p 9 An additional power supply may be required to maintain a minimum of 19 5 V at all devices There are two options to c...

Страница 15: ...ength for a single power supply WARNING Safety devices with OSSDs and without ISD such as safety light curtains are not compatible Failure to follow these instructions could result in serious injury o...

Страница 16: ...t Protection thermal digital clocking Switching Element Function PNP Normally Open Leakage Current Ir 1 mA DC Voltage Drop Ud 3 V Use Category DC 13 PNP OUT Auxiliary Output Rated Operating Current Ie...

Страница 17: ...5 4 26 19 36 7 6 22 7 8 1 4 5 Figure 11 SI RF Safety Switch Sensor 15 4 26 19 36 22 7 8 1 4 5 Figure 12 SI RF Safety Switch Actuator 2X 4 3 22 3 6 7 18 18 36 Figure 13 SI RF Safety Switch A2 Actuator...

Страница 18: ...te 3 Blue 4 Black 5 Gray MQDC1 506 2 m 6 5 ft MQDC1 515 5 m 16 4 ft MQDC1 530 9 m 29 5 ft MQDC1 506RA 2 m 6 5 ft Right Angle 32 Typ 1 26 30 Typ 1 18 14 5 0 57 M12 x 1 MQDC1 515RA 5 m 16 4 ft MQDC1 530...

Страница 19: ...2 ft MQDEC 450RS 15 2 m 49 9 ft 8 Pin Threaded M12 Euro Style Cordsets Double Ended Model 8 pin 8 pin 2 Length Style Dimensions Pinout DEE2R 81D 0 3 m 1 ft Female Straight Male Straight 40 Typ 14 5 M1...

Страница 20: ...tible I O and 2 Redundant Solid State Safety Outputs with Display SC26 2e XS26 2e 26 convertible I O and 2 Redundant Solid State Safety Outputs with Ethernet SC26 2de XS26 2de 26 convertible I O and 2...

Страница 21: ...ndicators Information for Color Status Meaning Power Fault Input LEDs Operating status Green On Sensor OK Flashing BC1 Reset expected only with reset input Flashing BC2 Input function not fulfilled Ac...

Страница 22: ...Data Format Meaning of data Actuator Detected 1 0 The SI RF sensor detects an actuator Note It does not have to be the taught actuator Wrong Actuator 1 0 SI RF sensor detects an actuator with a receiv...

Страница 23: ...remaining number of teaches available Note Low and already taught unique units display 0 Number of voltage errors number The number of voltage warnings received in the last 60 seconds voltage is chec...

Страница 24: ...FOR ANY EXTRA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING...

Отзывы: