7.2.4 Receiver Indicators
A single Status indicator shows when the OSSD outputs are on (green) or off (red), or the System is in a Lockout condition
(flashing red).
Zone indicators show whether a section of the defined area is aligned and clear, is blocked and/or misaligned, or is a section
that has a channel with a weak beam strength. All models have three Zone indicators, each of which indicates Blocked/Clear/
Weak Beam Strength conditions for approximately 1/3 of the total light screen.
Operating Mode
Status Indicator
Zone Indicators
5
OSSD Outputs
Power up
Red on for several seconds, then
green on for 1 second
Three LEDs red on, then flash
green, then yellow for 10 seconds to
indicate scan code.
•
Zone 2 only = Scan Code 1
•
Zone 2 and Zone 3 = Scan
Code 2
Off
Alignment mode - beam 1 blocked
Red
Zone 1 red, others off
Off
Alignment mode - beam 1 clear
Red
Red or green
Off
Run mode - clear
Green
All on green
On
Run Mode - clear with weak beam
strength
Green
Green or yellow
On
Run mode - blocked
Red
Red or green
Off
Lockout
Flashing red
•
Zone 1 = Output Error
OR
•
Zone 3 = Receiver Error
42 for more information.
Off
7.3 Periodic Checkout Requirements
To ensure continued reliable operation, the System must be checked out periodically. Banner Engineering highly
recommends performing the System checkouts as described below. However, a Qualified Person should evaluate these
recommendations, based on the specific application and the results of a machine risk assessment, to determine the
appropriate content and frequency of checkouts.
At every shift change, power-up, and machine setup change,
the Daily Checkout should be performed; this checkout
may be performed by a Designated or Qualified Person.
Semi-annually,
the System and its interface to the guarded machine should be thoroughly checked out; this checkout must
be performed by a Qualified Person (see
on page 44). A copy of these test results should be
posted on or near the machine.
Whenever changes are made to the System
(either a new configuration of the S4B System or changes to the machine),
perform the Commissioning Checkout (see
on page 36).
Note: Verify Proper Operation
The S4B can operate as it is designed only if it and the guarded machine are operating properly, both
separately and together. It is the user’s responsibility to verify this, on a regular basis, as instructed in
on page 44. Failure to correct such problems can result in an increased risk of
harm.
Before the System is put back into service, verify that the S4B System and the guarded machine perform
exactly as outlined in the checkout procedures and any problem(s) are found and corrected.
5 If beam 1 is blocked, Zone indicators 2–3 will be Off, because beam 1 provides the synchronization signal for all the beams.
S4B Safety Light Curtain
www.bannerengineering.com - Tel: + 1 888 373 6767
41