Banner RP-LS42F LE Series Скачать руководство пользователя страница 11

Model

Quantity

Description

Tensioning Spring

Used With

RPA-S3-1

1

Tensioning spring #3

RP-RM83 models (75 m)
RP-LS42 models (75 m)

RPA-S5-1

1

Tensioning spring #5

RP-RM83F-..38..
RP-LS42 models (25 & 38 m)

Model

Quantity

Description

Tensioning Spring

Used With

RPA-S4-1

1

Tensioning spring #4 with built-in eye bolt (used
with customer-supplied M12 × 1.75 pitch nut), cable
thimble, clamping, tensioning, and overload
protection.

RP-RM83 models (75 m)
RP-LS42 models (75 m)

RPA-S6-1

1

Tensioning spring #6 with built-in eye bolt (used
with customer-supplied M12 × 1.75 pitch nut), cable
thimble, clamping, tensioning, and overload
protection.

RP-RM83 models (38 m)
RP-LS42 models (25 & 38 m)

Rope Pull Hardware Kits

Note: 

Tensioning springs ordered separately

Kit Model

3 mm Rope

(Length)

Thimbles (Each)

Clamps (Each)

Eye Bolts

(Each)

In-Line Pulleys

(Each)

Turnbuckle

(Each)

RPAK-C2SBP-1

0.5 m (1.5 ft)

2

2

-

-

-

RPAK-CH2-10

10 m (32.8 ft)

4

4

3

-

-

RPAK-CHP2-10

4

4

3

3

-

RPAK-CH2-10-TA

4

4

3

-

1

RPAK-CHP2-10-TA

4

4

3

3

1

RPAK-CH2-20

20 m (65.6 ft)

4

4

6

-

-

RPAK-CHP2-20

4

4

6

6

-

RPAK-CH2-20-TA

4

4

6

-

1

RPAK-CHP2-20-TA

4

4

6

6

1

RPAK-CH2-40

40 m (131.2 ft)

4

4

11

-

-

RPAK-CHP2-40

4

4

11

11

-

RPAK-CH2-40-TA

4

4

11

-

1

RPAK-CHP2-40-TA

4

4

11

11

1

RPAK-CH2-50

50 m (164.0 ft)

4

4

14

-

-

RPAK-CHP2-50

4

4

14

14

-

RPAK-CH2-50-TA

4

4

14

-

1

RPAK-CHP2-50-TA

4

4

14

14

1

RPAK-CH2-80

80 m (262.4 ft)

4

4

21

-

-

RPAK-CHP2-80

4

4

21

21

-

RPAK-CH2-80-TA

4

4

21

-

1

RPAK-CHP2-80-TA

4

4

21

21

1

U.S. Application Standards

ANSI B11.0 Safety of Machinery, General Requirements, and Risk Assessment
ANSI B11.19 Performance Criteria for Safeguarding
NFPA 79 Electrical Standard for Industrial Machinery

International/European Standards

EN ISO 12100 Safety of Machinery – General Principles for Design — Risk Assessment and Risk Reduction

Rope Pull Emergency Stop Switches

 

 

P/N 67709 Rev. C

www.bannerengineering.com - Tel: + 1 888 373 6767

11

Содержание RP-LS42F LE Series

Страница 1: ...22 34 42 13 21 33 41 Run 14 22 34 42 13 21 33 41 Pull Break Note This symbol for a positive opening safety contact IEC 60947 5 1 is used in the switching diagram to identify the point in actuator tra...

Страница 2: ...cable pull The rope or cable pull as well as any flags or markers must be colored RED The rope or cable pull must have the capability to react to a force in any direction This requires a spring at the...

Страница 3: ...mbly RPA S4 1 or RPA S6 1 eye bolt to an anchor that is solid and stationary and can withstand the constant tension and pull of the rope Do not exceed the maximum length for the specific switch 3 For...

Страница 4: ...edian position to allow for adjustment in both directions b Attach the prepared turnbuckle to the rope using a thimble clamp loop Keep the rope s PVC cover intact along its complete length except wher...

Страница 5: ...e accomplished by pulling excess rope through the clamp until the tension indicator is approximately centered and then re tightening the clamp It is recommended that tensioning be accomplished at a me...

Страница 6: ...s to the terminals 1 Insert the screwdriver blade flat 2 5 mm into the slot next to the desired wiring terminal 2 Twist the screwdriver blade 45 in the slot to open the terminal jaws insert the wire 6...

Страница 7: ...series Never connect the contacts of multiple switches in parallel Individually actuate engage each device then release or re arm and reset the safety module This allows the module to check each switc...

Страница 8: ...Type gG Recommend external fusing or overload protection B10d 1 x 105 cycles at DC 13 24 V Ie2 0 1 A Mechanical Life 1 x 105 switching cycles maximum according to IEC 60947 5 5 Wire Connections 8 x ca...

Страница 9: ...ion 130 mm 5 in flying lead wires 1 each 30 27 M20 X 1 5 SI K30LRXX7P 1 RED indication 1 each SI K30LYRX7P 2 YELLOW RED indication 1 each Cable Gland Model Size For Cable Diameter Dimensions Used With...

Страница 10: ...8 ft 3 mm steel wire rope with 0 5 mm red PVC jacket unterminated RPA C2 20 20 m 65 6 ft RPA C2 40 40 m 131 2 ft RPA C2 50 50 m 164 0 ft RPA C2 80 80 m 262 4 ft Model Quantity Description Thimble RPA...

Страница 11: ...Turnbuckle Each RPAK C2SBP 1 0 5 m 1 5 ft 2 2 RPAK CH2 10 10 m 32 8 ft 4 4 3 RPAK CHP2 10 4 4 3 3 RPAK CH2 10 TA 4 4 3 1 RPAK CHP2 10 TA 4 4 3 3 1 RPAK CH2 20 20 m 65 6 ft 4 4 6 RPAK CHP2 20 4 4 6 6...

Страница 12: ...IVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF...

Отзывы: