Set the Sensitivity
Use Sensitivity Selection to set the signal strength threshold.
1. Access Sensitivity Selection.
Action
Result
Triple-pulse the remote input.
T
T
T
T
T
The green power LED flashes slowly.
2. Select the desired signal threshold.
Action
Result
Pulses
TEACH Mode
1
T
Signal Strength Threshold = 1
2
T
T
T
Signal Strength Threshold = 2
3
T
T
T
T
T
Signal Strength Threshold = 3
4
T
T
T
T
T
T
T
Signal Strength Threshold = 5
5
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 10
6
T
T
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 15
7
T
T
T
T
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 20
8
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 30
The signal threshold is set and
the green power LED flashes
equal to the number of pluses,
pauses, and then flashes equal
to the number of pulses a
second time. Then the sensor
exits remote teach and returns
to run mode.
Set the Speed
Use Speed Selection to set the speed of the sensor.
1. Access Speed Selection.
Action
Result
Four-pulse the remote input.
T
T
T
T
T
T
T
The green power LED flashes slowly.
2. Select the desired signal threshold.
R-GAGE
®
T30R Sensor
18