Figure 10. Remote Input Map
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
Pulse Timing (T)
Gray wire is remote teach input
3x
1x
1
2x
2
3x
3
4x
5
5x
10
6x
15
7x
20
8x
30
Sensitivity Selection
4x
1x
Fast
2x
Medium
3x
Slow
Speed Selection
5x
1x
Nearest Target
2x
Strongest Target
Target Selection Mode
8x
Reset to Factory Defaults
10x
Enable/Disable Remote Teach
Remote
Input
1x
Remote Teach
1x
Teach Output 1 4mA/SPt 1
1x
Teach Output 1 20mA/SPt 2
2x
Teach Output 2 SPt 1
1x
Teach Output 1 SPt 2
2x
Remote Setup
1x
Output 1 Mode/Slope (analog output for analog model, use
discrete menu options below for dual discrete model)
1x
Positive Slope
2x
Negative Slope
2x
Output 2 Mode/Slope (discrete output)
1x
NO
2x
NC
3x
SPt Background Teach
4x
SPt Object Teach
5x
Window Teach
Note:
If a factory reset is performed through the Banner Radar Configuration Software, the remote input
wire becomes disabled (factory default setting). If the sensor is returned to factory defaults by using the
remote input wire, the input wire remains enabled and the rest of the settings are restored to factory
defaults.
R-GAGE
®
T30R Sensor
16
www.bannerengineering.com - Tel: + 1 888 373 6767