4 Windows
The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the
distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20%
signal reduction when the sensor is placed behind a window.
Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials. Thinner
(1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and distance from
the sensor to the window.
Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance between
the sensor and the window. The positions of maximum reflection from the window repeat between the minimums, and
decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window
materials which can be used at any distance without issue.
Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood
directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face
of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of the
window can be detected as a dielectric boundary.
R-GAGE
®
Q130RA-AF Sensor
8
www.bannerengineering.com - Tel: +1.763.544.3164
DRAFT