background image

1 Product Description

Radar-Based Sensors for Detection of Moving and Stationary Targets

Placeholder

• FMCW (true-presence) radar detects moving and stationary objects
• Adjustable sensing field — ignores objects beyond setpoint
• Easy setup and configuration of range, sensitivity, and output with simple DIP

switches

• Easy setup and configuration of range, sensitivity, and output using a PC
• Sensing functions are unaffected by wind, falling rain or snow, fog, humidity, air

temperatures, or light

• Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunication

band

• Rugged IP67 housing withstands harsh environments

Protected by US patents.

CAUTION: Make No Modifications to this Product
Any modifications to this product not expressly approved by Banner Engineering could void the user's

authority to operate the product. Contact Banner Engineering for more information.

WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury

or death. This device does not include the self-checking redundant circuitry necessary to allow its use in

personnel safety applications. A sensor failure or malfunction can cause either an energized or de-

energized sensor output condition.

1.1 Models

Models

Maximum
Range

Beam
Angle

Telecom Approval1

Output

Connection

Q130RA-9076-AFQ

24 m (78 ft)

90° × 76°

Telecom approved for US, Canada and

Brazil

Bipolar NPN/PNP

N.O./N.C.

Configurable

5-wire 2 m

(6.5 ft)

Integral

cable

Q130RA-2450-AFQ

24° × 50°

Telecom approved for Europe, UK,

Australia, New Zealand, China, and Japan

1.2 Overview

The R-GAGE sensor emits a well-defined beam of high-frequency radio waves from an internal antenna. Some of this

emitted energy reflects back to the receiving antenna. Signal processing electronics in the sensor determine the distance

from the sensor to the object based on the time delay of the return signal. The sensor can be configured (using a PC) to

sense objects up to a specific distance, ignoring objects beyond this distance (also called background suppression).

1 For additional countries, contact Banner Engineering.

 

 

R-GAGE

®

 Q130RA-AF Sensor

 

www.bannerengineering.com - Tel: +1.763.544.3164

3

DRAFT

Содержание R-Gage Q130RA-AF

Страница 1: ...R GAGE Q130RA AF Sensor Instruction Manual Original Instructions TBD Rev A 31 October 2018 Banner Engineering Corp All rights reserved TBD D R A F T ...

Страница 2: ... Installation Instructions 5 2 1 Mount the Device 5 2 2 Wiring 5 3 Specifications 6 3 1 Beam Patterns 6 3 2 Dimensions 7 4 Windows 8 5 Accessories 9 5 1 Quick Disconnect QD Cordsets 9 5 2 Brackets and Enclosures 9 6 Banner Engineering Corp Limited Warranty 10 R GAGE Q130RA AF Sensor D R A F T ...

Страница 3: ...ld lead to serious injury or death This device does not include the self checking redundant circuitry necessary to allow its use in personnel safety applications A sensor failure or malfunction can cause either an energized or de energized sensor output condition 1 1 Models Models Maximum Range Beam Angle Telecom Approval1 Output Connection Q130RA 9076 AFQ 24 m 78 ft 90 76 Telecom approved for US ...

Страница 4: ...R GAGE Features 1 Power LED Green power ON 2 Signal Strength LED Red flashes in proportion to the signal strength 3 Output LEDs Yellow output energized Red configuration R GAGE Q130RA AF Sensor 4 www bannerengineering com Tel 1 763 544 3164 D R A F T ...

Страница 5: ...alignment 4 Tighten the mounting screws to secure the device or the device and the bracket in the aligned position 2 2 Wiring shield QD cordset 3 1 2 4 5 12 30V dc Load 1 Load 2 Wiring Key 1 Brown 2 White 3 Blue 4 Black 5 Gray Do not connect Note Banner recommends that the shield wire QD cordsets only be connected to earth ground or dc common Shielded cordsets are recommended for all QD models R G...

Страница 6: ...rgized Red configuration See Figure 1 on page 4 Construction Housing ABS polycarbonate Lightpipes Acrylic Access Cap Polyester Operating Temperature 40 C to 65 C 40 F to 149 F Environmental Rating IEC IP67 Connections Integral 5 wire 2 m 6 5 ft cable or M12 Euro style QD fitting QD models require a mating cordset Certifications 3 1 Beam Patterns Typical Beam Pattern with BRTR CC20E Radar Target Ra...

Страница 7: ...3 2 Dimensions All measurements are listed in millimeters inches unless noted otherwise Placeholder R GAGE Q130RA AF Sensor www bannerengineering com Tel 1 763 544 3164 7 D R A F T ...

Страница 8: ...ndow which will repeat every 6 1 mm of distance between the sensor and the window The positions of maximum reflection from the window repeat between the minimums and decrease in effect until the window is approximately 150 mm 5 9 in away Consult the factory for pre tested window materials which can be used at any distance without issue Additionally the face of the window should be protected from f...

Страница 9: ...5 2 Brackets and Enclosures SMBQ240SS1 Sensor mounting plate and pivoting bracket Provides 20 of tilt in one axis for enhanced sensor alignment 12 gauge stainless steel Sensor can mount on bracket horizontally or vertically SMBQ240SS2 Add on accessory to be used in conjunction with SMBQ240SS1 Provides 20 of tilt in second axis for maximum control of sensor alignment 12 gauge stainless steel SMBWSQ...

Страница 10: ...UENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWISE Banner Engineering Corp reserves the right to change modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by B...

Отзывы: