2 Installation Instructions
2.1 Install the Software
Important:
Administrative rights are required to install the Banner Radar Configuration software.
1. Download the latest version of the software from
www.bannerengineering.com/us/en/products/sensors/software/
2. Navigate to and open the downloaded file.
3. Click
Install
to begin the installation process.
4. Depending on your system settings, a popup window may appear prompting to allow Banner Radar Configuration to
make changes to your computer. Click
Yes
.
5. Click
Close
to exit the installer.
2.2 Sensor Orientation
Correct sensor-to-object orientation is important to ensure proper sensing.
Minimize the tilt angle of a target relative to the sensor. The target should be tilted less than half of the beam angle.
Figure 4. Tilt angle of the target relative to the sensor
Recommended
target
target
Not Recommended
θ
T
θ
BA
θ
BA
θ
BA
θ
T
< 1/2 x
K50R
K50R
2.3 Mount the Device
1. If a bracket is needed, mount the device onto the bracket.
2. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten
the mounting screws at this time.
3. Check the device alignment.
4. Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.
R-GAGE
®
K50R Radar Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767