Set the Sensitivity
Use Sensitivity Selection to set the signal strength threshold.
Note:
If Indication is disabled from the Banner Radar Configuration Software or a Pro model is being used,
no LEDs are active during the following procedure.
1. Access Sensitivity Selection.
Action
Result
Triple-pulse the remote input.
T
T
T
T
T
The Power/Signal LED flashes.
2. Select the desired signal threshold.
Action
Result
Pulses
TEACH Mode
1
T
Signal Strength Threshold = 1
2
T
T
T
Signal Strength Threshold = 2
3
T
T
T
T
T
Signal Strength Threshold = 3
4
T
T
T
T
T
T
T
Signal Strength Threshold = 4
5
T
T
T
T
T
T
T
T
T
Signal Strength Threshold = 5
The signal threshold is set and
the Power/Signal LED flashes
green equal to the number of
pluses, pauses, and then
flashes equal to the number of
pulses a second time. Then the
sensor exits remote teach and
returns to run mode.
Set the Speed
Use Speed Selection to set the speed of the sensor.
Note:
If Indication is disabled from the Banner Radar Configuration Software or a Pro model is being used,
no LEDs are active during the following procedure.
1. Access Speed Selection.
Action
Result
Four-pulse the remote input.
T
T
T
T
T
T
T
The Power/Signal LED flashes.
2. Select the desired signal threshold.
Action
Result
Pulses
TEACH Mode
1
T
Speed = Fast
2
T
T
T
Speed = Medium
3
T
T
T
T
T
Speed = Slow
The speed is set and the Power/Signal LED
flashes green equal to the number of pluses,
pauses, and then flashes equal to the
number of pulses a second time. The sensor
exits remote teach and returns to run mode.
R-GAGE
®
K50R Radar Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767