![Banner Q5XKLAF2000-Q8 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/banner/q5xklaf2000-q8/q5xklaf2000-q8_instruction-manual_3721343031.webp)
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
www.bannerengineering.com
.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
Shock
MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y and Z
axes, 18 shocks), with sensor operating
Operating Conditions
–10 °C to +50 °C (+14 °F to +122 °F)
35% to 95% relative humidity
Storage Temperature
–25 °C to +70 °C (–13 °F to +158 °F)
Certifications
Industrial
Control
Equipment
3TJJ
Class 2 power
UL Environmental Rating: Type 1
Excess Gain
Excess Gain Using a 90% White Card
2
Response Speed (ms)
at 100 mm
at 500 mm
at 1000 mm
at 2000 mm
3
150
50
15
4
5
150
50
15
4
15
725 (225)
250 (75)
70 (25)
15 (6)
25
1250 (800)
450 (250)
125 (70)
30 (15)
50
2500 (1250)
900 (450)
250 (125)
60 (30)
2
Standard excess gain available in 15, 25, and 50 ms response speeds; standard excess gain provides increase noise immunity.
Q5X Laser Triangulation Sensor with Background Suppression
www.bannerengineering.com - Tel: +1.763.544.3164
31