Setting
Factory Default
TEACH Mode (
)
—Two-point TEACH
Zero Reference Location (
)
—Measurement increases further from sensor
Hysteresis (
)
—Sensor controls value
Display Units (
)
—Centimeters
Output Polarity (
)
—Default: IO-Link on pin 4 and PNP on pin 2
3.3 Manual Adjustments
Manually adjust the sensor switch point using the
and
buttons.
1. From Run mode, press either
or
one time. The selected channel displays briefly, then the current switch
point value flashes slowly.
2. Press
to move the switch point up or
to move the switch point down. After 1 second of inactivity, the new
switch point value flashes rapidly, the new setting is accepted, and the sensor returns to Run mode.
Note: When FGS mode is selected (FGS indicator is on), manual adjustment moves both sides of the
symmetrical threshold window simultaneously, expanding and collapsing the window size. Manual
adjustment does not move the center point of the window.
Note: When dual mode is selected (DYN, FGS, and BGS indicators are on), after the TEACH process is
completed, use the manual adjustment to adjust the sensitivity of the thresholds around the taught
reference point. The taught reference point is a combination of the measured distance and returned signal
intensity from the reference target. Manual adjustment does not move the taught reference point, but
pressing
increases the sensitivity, and pressing
decreases the sensitivity. When re-positioning the
sensor or changing the reference target, re-teach the sensor.
3.4 Remote Input
Remote input is available from the Channel 2 menu. Set Out2 to Set.
Use the remote input to program the sensor remotely. The remote input provides limited programming options and is Active
high. For Active high, connect the white input wire to ground (0 V dc), with a remote switch connected between the wire and
ground.Pulse the remote input according to the diagram and the instructions provided in this manual.
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by setting the remote input high for longer than 2 seconds.
Q5X Laser Triangulation Sensor with Background Suppression
18
www.bannerengineering.com - Tel: +1.763.544.3164