Sensor Menu Map
no: do not reset to factory defaults
yes: reset to factory defaults
Two-Point Static Teach
Dynamic Teach
Light Set
Window Set
Top Menu
Sub Menu
off: no delays enabled
on: enable on and/or off delay (set value in Delay Timer menu)
1 Shot, fixed output pulse duration
LO = Single fixed duration, On pulse when moving into light state
DO = Single fixed duration, On pulse when moving into dark state
sec range, set Delay Timer value (seconds have decimal)
laser off when pulled low
laser on when pulled low
set: Remote Teach input
off: input is not active, ignore pulses
Master sync line for two sensor cross talk avoidance (response speed is 25 ms)
Slave sync line for two sensor cross talk avoidance (response speed is 25 ms)
display on
display on, inverted
display off (enters sleep mode after 60 seconds)
display off, inverted (enters sleep mode after 60 seconds)
end: exit setup
to
Teach Process Selection
Output Operation
Response Speed
Output Timing Delays
Delay Timer
Input Wire Function
Sensitivity
Display Read
Exit Setup
Reset to Factory Defaults
Available when
set to “1Sh”
Available when
set to “on”
ms
( default setting)
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
Light Operate
Dark Operate
Dark Set
(min, 10, 20, 30, 40, 50) - Window & Light Set options (20% is default for Light Set and Window)
(min, 25, 50, 100, 200) - Dark Set options ( 50% is default for Dark Set)
set Response Speed to 250 microseconds
set Response Speed to 1 millisecond
set Response Speed to 5 milliseconds
Offset Percentage
high sensitivity
low sensitivity
standard sensitivity
Menu not present when is set to “off”
("ond" and "ofd" default to 0, “dt1” defaults to 1 or 10 depending on response speed setting)
Pct menu present when teach is set to Window, Light, or Dark
BOTH
sets
selection
Cut-off Output Operation
BOTH
Output switches OFF when target is beyond background suppression distance
Output switches ON when target is beyond background suppression distance
Output follows LO/DO selection; sensor treats target in background as dark state
Response Speed menu not present when Input Wire Function set to Master or Slave
CtO menu present on LD50 models only
Figure 12. Setup Mode Menu Map
Q3X Laser Contrast Sensor
www.bannerengineering.com - Tel: +1-763-544-3164