background image

Sensor Menu Map

no: do not reset to factory defaults

yes: reset to factory defaults

Two-Point Static Teach
Dynamic Teach

Light Set

Window Set

Top Menu

Sub Menu

off: no delays enabled
on: enable on and/or off delay (set value in Delay Timer menu)
1 Shot, fixed output pulse duration

LO = Single fixed duration, On pulse when moving into light state
DO = Single fixed duration, On pulse when moving into dark state

sec range, set Delay Timer value (seconds have decimal)

laser off when pulled low
laser on when pulled low
set: Remote Teach input

off: input is not active, ignore pulses

Master sync line for two sensor cross talk avoidance (response speed is 25 ms)

Slave sync line for two sensor cross talk avoidance (response speed is 25 ms)

display on

display on, inverted

display off (enters sleep mode after 60 seconds)

display off, inverted (enters sleep mode after 60 seconds)

end: exit setup

to

Teach Process Selection

Output Operation

Response Speed

Output Timing Delays

Delay Timer

Input Wire Function

Sensitivity

Display Read

Exit Setup

Reset to Factory Defaults

Available when 

set to “1Sh”

Available when 

set to “on”

ms

(     default setting)

BOTH

BOTH

BOTH

BOTH

BOTH

BOTH

BOTH

BOTH

BOTH

BOTH

BOTH

Light Operate

Dark Operate

Dark Set

(min, 10, 20, 30, 40, 50) - Window & Light Set options (20% is default for Light Set and Window) 
(min, 25, 50, 100, 200) - Dark Set options ( 50% is default for Dark Set)

set Response Speed to 250 microseconds
set Response Speed to 1 millisecond
set Response Speed to 5 milliseconds

Offset Percentage

high sensitivity
low sensitivity

standard sensitivity

Menu not present when           is set to “off” 
("ond" and "ofd" default to 0, “dt1” defaults to 1 or 10 depending on response speed setting)

Pct menu present when teach is set to Window, Light, or Dark

BOTH

sets 

selection

Cut-off Output Operation

BOTH

Output switches OFF when target is beyond background suppression distance
Output  switches ON when target is beyond background suppression distance

Output follows LO/DO selection; sensor treats target in background as dark state

Response Speed menu not present when Input Wire Function set to Master or Slave

CtO menu present on LD50 models only

Figure 12. Setup Mode Menu Map

 

 

Q3X Laser Contrast Sensor

 

www.bannerengineering.com - Tel: +1-763-544-3164

 

Содержание Q3XTBLD-Q8

Страница 1: ... Amber WND Symmetric window thresholds are active Amber In Run mode the 3 digit 7 segment display provides real time information about signal strength for all models and target position for models with a fixed background suppression distance The numeric value of 0 to 990 represent the amount of the received light divided by the threshold and represents the excess gain of the sensing event expresse...

Страница 2: ...are above and below 100 by the offset percentage Buttons Use the sensor buttons MODE and TEACH to program the sensor See Sensor Programming on page 4 for programming instructions MODE Decrease gain press and release MODE then press and hold MODE to rapidly decrease gain Enter Setup mode press and hold MODE for longer than 2 seconds Navigate the sensor menu press MODE Change setting values press an...

Страница 3: ...el together Figure 3 Safety Label Installation Sensor Orientation Correct sensor to target orientation is important to ensure proper sensing To ensure reliable detection orient the sensor as shown in relation to the target to be detected For models with background suppression make sure the intended target is inside of the contrast sensing range and that any background objects are positioned beyond...

Страница 4: ...idental programming changes See the Instruction Manual for more information Setup Mode 1 Access Setup mode from Run mode by pressing and holding MODE for longer than 2 seconds 2 Use or to navigate through the top menu 3 Select the desired submenu by pressing and simultaneously 4 Press or to view the available options in the submenu 5 Select a submenu option Press and simultaneously to select and s...

Страница 5: ... sensor s gain or press and hold or to rapidly decrease or increase gain After 1 second the normalized signal strength flashes rapidly the new setting is accepted and the sensor returns to Run mode Locking and Unlocking the Sensor Buttons Use the lock and unlock feature to prevent unauthorized or accidental programming changes To lock or unlock the sensor using the buttons press and hold and immed...

Страница 6: ...Figure 11 Beam Pattern NOTE For high sensitivity the excess gain increases by a factor of 1 5 For low sensitivity the excess gain decreases by a factor of 0 75 Specifications Sensing Beam Visible red Class 2 laser 655 nm Supply Voltage Vcc 10 to 30 V dc Power and Current exclusive of load Supply Power 675 mW Current consumption 28 mA at 24 V dc Supply Protection Circuitry Protected against reverse...

Страница 7: ...by qualified personnel in accordance with local and national electrical codes and regulations Supply Wiring Required Overcurren t Protection 20 5 0 Amps 22 3 0 Amps 24 2 0 Amps 26 1 0 Amps 28 0 8 Amps 30 0 5 Amps Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Bann...

Страница 8: ...d Exit Setup Reset to Factory Defaults Available when set to 1Sh Available when set to on ms default setting BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH Light Operate Dark Operate Dark Set min 10 20 30 40 50 Window Light Set options 20 is default for Light Set and Window min 25 50 100 200 Dark Set options 50 is default for Dark Set set Response Speed to 250 microseconds set Response Spe...

Отзывы: