background image

1. Press and hold TEACH for longer than 2 seconds to start the selected TEACH mode.
2. Present the target.
3. Press TEACH to teach the target. The target is taught and the sensor waits for the second target, if required by the

selected TEACH mode, or returns to Run mode.

Complete steps 4 and 5 only if prompted by the sensor for the selected TEACH mode:

4. Present the second target.
5. Press TEACH to teach the target. The target is taught and the sensor returns to Run mode.

See the Instruction Manual for detailed instructions and other available TEACH modes.

Manual Adjustments

Manually increase or decrease gain using 

 or 

.

1. From Run mode, press either 

 or 

 one time. The current signal strength value flashes slowly.

2. Press 

 to decrease the sensor's gain or 

 to increase the sensor's gain, or press and hold 

 or 

 to rapidly

decrease or increase gain. After 1 second, the normalized signal strength flashes rapidly, the new setting is

accepted, and the sensor returns to Run mode.

Locking and Unlocking the Sensor Buttons

Use the lock and unlock feature to prevent unauthorized or accidental programming changes.

To lock or unlock the sensor using the buttons, press and hold 

 and immediately press 

 four times.

Performance Curves

Performance is based on a 90% reflectance white test card.

Q3XTBLD Models

DISTANCE (mm)

EXCESS

 GAIN

1

1

10

10

100

100

1000

1000

Figure 5. Excess Gain for Standard

Sensitivity

DISTANCE (mm)

0

50

100

150

200

250

300

BEA

M

 P

ATTERN (mm)

-2.5

-2.0

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

2.0

2.5

Figure 6. Beam Pattern

NOTE: For high

sensitivity, the

excess gain

increases by a

factor of 1.5. For

low sensitivity, the

excess gain

decreases by a

factor of 0.75

Q3X Laser Contrast Sensor

 

 

P/N 181486 Rev. D

www.bannerengineering.com - Tel: +1-763-544-3164

5

Содержание Q3XTBLD-Q8

Страница 1: ... Amber WND Symmetric window thresholds are active Amber In Run mode the 3 digit 7 segment display provides real time information about signal strength for all models and target position for models with a fixed background suppression distance The numeric value of 0 to 990 represent the amount of the received light divided by the threshold and represents the excess gain of the sensing event expresse...

Страница 2: ...are above and below 100 by the offset percentage Buttons Use the sensor buttons MODE and TEACH to program the sensor See Sensor Programming on page 4 for programming instructions MODE Decrease gain press and release MODE then press and hold MODE to rapidly decrease gain Enter Setup mode press and hold MODE for longer than 2 seconds Navigate the sensor menu press MODE Change setting values press an...

Страница 3: ...el together Figure 3 Safety Label Installation Sensor Orientation Correct sensor to target orientation is important to ensure proper sensing To ensure reliable detection orient the sensor as shown in relation to the target to be detected For models with background suppression make sure the intended target is inside of the contrast sensing range and that any background objects are positioned beyond...

Страница 4: ...idental programming changes See the Instruction Manual for more information Setup Mode 1 Access Setup mode from Run mode by pressing and holding MODE for longer than 2 seconds 2 Use or to navigate through the top menu 3 Select the desired submenu by pressing and simultaneously 4 Press or to view the available options in the submenu 5 Select a submenu option Press and simultaneously to select and s...

Страница 5: ... sensor s gain or press and hold or to rapidly decrease or increase gain After 1 second the normalized signal strength flashes rapidly the new setting is accepted and the sensor returns to Run mode Locking and Unlocking the Sensor Buttons Use the lock and unlock feature to prevent unauthorized or accidental programming changes To lock or unlock the sensor using the buttons press and hold and immed...

Страница 6: ...Figure 11 Beam Pattern NOTE For high sensitivity the excess gain increases by a factor of 1 5 For low sensitivity the excess gain decreases by a factor of 0 75 Specifications Sensing Beam Visible red Class 2 laser 655 nm Supply Voltage Vcc 10 to 30 V dc Power and Current exclusive of load Supply Power 675 mW Current consumption 28 mA at 24 V dc Supply Protection Circuitry Protected against reverse...

Страница 7: ...by qualified personnel in accordance with local and national electrical codes and regulations Supply Wiring Required Overcurren t Protection 20 5 0 Amps 22 3 0 Amps 24 2 0 Amps 26 1 0 Amps 28 0 8 Amps 30 0 5 Amps Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Bann...

Страница 8: ...d Exit Setup Reset to Factory Defaults Available when set to 1Sh Available when set to on ms default setting BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH Light Operate Dark Operate Dark Set min 10 20 30 40 50 Window Light Set options 20 is default for Light Set and Window min 25 50 100 200 Dark Set options 50 is default for Dark Set set Response Speed to 250 microseconds set Response Spe...

Отзывы: