background image

Quick Start Guide

Laser Expert

 diffuse sensor with bipolar (1 PNP & 1 NPN) output. Patent pending.

This guide is designed to help you set up and install the Q3X Sensor. For complete information on programming,

performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at 

www.bannerengineering.com

. Search for p/n 181485 to view the manual. Use of this document assumes familiarity with

pertinent industry standards and practices.

WARNING: Not To Be Used for Personnel Protection

Never use this device as a sensing device for personnel protection. Doing so could lead to

serious injury or death. This device does not include the self-checking redundant circuitry necessary

to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an

energized or de-energized sensor output condition.

Features

1

3

2

Figure 1. Sensor Features

1. Output Indicator (Amber)
2. Display
3. Buttons

Display and Indicators

Figure 2. Display in Run Mode

1. Stability Indicator (STB = Green)
2. Active TEACH Indicators

DYN = Dynamic TEACH selected (Amber)

WND = Symmetric window thresholds are

active (Amber)

In Run mode, the 3-digit, 7-segment display provides real time information about signal strength for all models and target

position for models with a fixed background suppression distance. The numeric value of 0 to 990 represent the amount of

the received light divided by the threshold, and represents the excess gain of the sensing event expressed as a percentage

of the switch point. This value is called normalized signal strength (NSS). A NSS display range of 999 indicates a saturated

received light signal, meaning that low contrast detection is not possible.

In single threshold teach modes (Two-Point Static, Dynamic, Light Set, or Dark Set), the output switches at a displayed

value of 100 (excess gain of 1.0).

For models with a specified background suppression distance, 

 indicates that a target is present at a distance beyond

the background suppression distance and is being suppressed. In Light Operate mode, the output switches off when 

displays. For the LD50 models, the sensor's output state when displaying 

 can be controlled using the 

 menu.

By default, the sensor treats a target in the background as a dark signal and honors the LO/DO selection.

Q3X Laser Contrast Sensor

 

 

Original Document

181486 Rev. D

21 May 2015

181486

Содержание Q3XTBLD-Q8

Страница 1: ... Amber WND Symmetric window thresholds are active Amber In Run mode the 3 digit 7 segment display provides real time information about signal strength for all models and target position for models with a fixed background suppression distance The numeric value of 0 to 990 represent the amount of the received light divided by the threshold and represents the excess gain of the sensing event expresse...

Страница 2: ...are above and below 100 by the offset percentage Buttons Use the sensor buttons MODE and TEACH to program the sensor See Sensor Programming on page 4 for programming instructions MODE Decrease gain press and release MODE then press and hold MODE to rapidly decrease gain Enter Setup mode press and hold MODE for longer than 2 seconds Navigate the sensor menu press MODE Change setting values press an...

Страница 3: ...el together Figure 3 Safety Label Installation Sensor Orientation Correct sensor to target orientation is important to ensure proper sensing To ensure reliable detection orient the sensor as shown in relation to the target to be detected For models with background suppression make sure the intended target is inside of the contrast sensing range and that any background objects are positioned beyond...

Страница 4: ...idental programming changes See the Instruction Manual for more information Setup Mode 1 Access Setup mode from Run mode by pressing and holding MODE for longer than 2 seconds 2 Use or to navigate through the top menu 3 Select the desired submenu by pressing and simultaneously 4 Press or to view the available options in the submenu 5 Select a submenu option Press and simultaneously to select and s...

Страница 5: ... sensor s gain or press and hold or to rapidly decrease or increase gain After 1 second the normalized signal strength flashes rapidly the new setting is accepted and the sensor returns to Run mode Locking and Unlocking the Sensor Buttons Use the lock and unlock feature to prevent unauthorized or accidental programming changes To lock or unlock the sensor using the buttons press and hold and immed...

Страница 6: ...Figure 11 Beam Pattern NOTE For high sensitivity the excess gain increases by a factor of 1 5 For low sensitivity the excess gain decreases by a factor of 0 75 Specifications Sensing Beam Visible red Class 2 laser 655 nm Supply Voltage Vcc 10 to 30 V dc Power and Current exclusive of load Supply Power 675 mW Current consumption 28 mA at 24 V dc Supply Protection Circuitry Protected against reverse...

Страница 7: ...by qualified personnel in accordance with local and national electrical codes and regulations Supply Wiring Required Overcurren t Protection 20 5 0 Amps 22 3 0 Amps 24 2 0 Amps 26 1 0 Amps 28 0 8 Amps 30 0 5 Amps Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Bann...

Страница 8: ...d Exit Setup Reset to Factory Defaults Available when set to 1Sh Available when set to on ms default setting BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH BOTH Light Operate Dark Operate Dark Set min 10 20 30 40 50 Window Light Set options 20 is default for Light Set and Window min 25 50 100 200 Dark Set options 50 is default for Dark Set set Response Speed to 250 microseconds set Response Spe...

Отзывы: