Model
Default Nominal Thickness
Ideal Master/Slave
Separation
LH150
50 mm
350 mm
The ideal master/slave
separation
can be calculated by the following formula:
Ideal
Separation
= 2 * Reference Di Nominal Thickness
For example: LH30 with 14mm nominal thickness would be calculated as follows: Ideal
Separation
= 2 * 30 + 14 = 74 mm
(see
for Reference Distance)
If the ideal master/slave
separation
cannot be achieved due to
application
restrictions,
the thickness delta measurement can
still
be
configured
to work properly by
adjusting
the Thickness Delta
Offset
parameter via the Banner LH Series
Configurator
software.
Thickness Delta Measurement
Installation
Steps:
1. Adjust the
separation
distance between the Master and Slave sensors as required by the
application.
2. The Master and Slave sensors must be aligned to the target so the laser beam strikes the target surface at a right angle.
3. Secure both sensors with 3 bolts of 4 mm diameter.
4.
Attach
the M12 cord set and complete wiring of both sensors.
LH Series
SLAVE
LH Series
MASTER
TARGET
Master’s
Measurement
Range
Slave’s
Measurement
Range
Master/Slave Separation
Motion of
TARGET must be
perpendicular to
emitter/receiver
axis.
2.3 Handling and Storage
The LH Series Laser Displacement Sensor is an
optical
instrument capable of micometer-level
resolutions.
CAUTION: The sensors are delivered in shock-resistant packaging. Always handle/transport the sensors carefully to avoid rough
handling. The sensors must be stored in a dry place and should not be subjected to extreme temperature
fluctuations.
L-GAGE
®
LH Series Sensor
6
www.bannerengineering.com - Tel: 763.544.3164