2 LH Series
Installation
and Setup
2.1 Cable/Connector Wiring
Pin
Color
Description
18-30V dc
–
+
2
7
–
+
1
4-20 mA
3
5
6
4
8
Shield/Drain
Wire*
RS-485 GND
RS-485 RX+/TX+
RS-485 RX-/TX-
1
White
4-20 mA output source
2
Brown
Power supply 18–30 V dc
3
Shield (bundled with white
wire inside blue foil wrap)
4-20 mA output return
4
Yellow
RS-485 RX- / TX-
5
Grey
Ground of RS-485 bus
6
Green
RS-485 RX+ / TX+
7
Blue
Ground
8
Shield
Shield/drain wire*
* The shield/drain wire is connected internally to the sensor housing and should be connected as follows:
1. If the sensor housing is mounted so that it is in
continuity
with both the machine frame and earth ground, connect the shield/
drain wire (also) to earth ground.
2. If the sensor housing is mounted so that it is insulated from the machine frame, connect the shield/drain wire to -V dc (together
with the blue wire).
3. If the sensor is mounted so that it is in
continuity
with the machine frame, but not with earth ground, do not connect the
shield/drain wire (i.e. cut
off
the shield/drain wire).
2.2
Installation
The LH Series Laser Displacement Sensor is an
optical
instrument capable of micrometer-level
resolutions.
Note: Handle the sensor with care when installing and
operating.
Applications
requiring measurement
resolution
in the
micrometer range must take
vibration,
dust, and thermal expansion
effects
into
consideration.
Windows of all sensors must be
clean for full
functionality.
Windows that are soiled by dust, water, oil, etc may cause the sensor to not operate correctly. The
windows should be cleaned thoroughly whenever necessary, using a high quality glass cleaner.
2.2.1 Displacement Measurement
Installation
1. Adjust the distance between the sensor head and the target so the target is near the middle of the measurement range.
2. The sensor must be aligned to the target so the laser beam strikes the target surface at a right angle.
3. Secure the sensor with 3 bolts of 4 mm diameter.
4.
Attach
the M12 cord set and complete wiring of the sensor.
L-GAGE
®
LH Series Sensor
4
www.bannerengineering.com - Tel: 763.544.3164