3.5 Discrete Output Menu (Dx_OUT)
Use this menu to view or change
•
Setpoints
•
Midpoint
•
Mode
•
Timers
•
Polarity
The menu options are identical for
D1_OUT and D2_OUT.
MENU D1_OUT
or
or
Go Back to Parent Menu
Select Menu Item
Press to Save Setting
Press and Hold to Go Back
to Run Mode
OffDly 0 ms
Off1Sho 0 ms
OnDly 0 ms
On1Sho 0 ms
TchSPt1 100 mm
TchSPt2 1000 mm
Tch2Pt TchSPt2
Tch2Pt TchSPt1
Mode Health
Mode Alarm
Timer On1Sho
Timer OffDly
Mode Swtch
Mode Swtch
Mode Wnd
Mode Wnd
Timer Off1Sho
Timer OnDly
AdjSPt2 1000 mm
AdjSPt1 100 mm
D1_OUT Tch2Pt
D1_OUT Mode
D1_OUT Timer
D1_OUT AdjSPt1
D1_OUT AdjSPt2
(in Swtch mode only)
WndSize 300 mm
TchMdPt 500 mm
TchMid TchMdPt
TchMid WndSize
D1_OUT TchMid
Offset 0 mm
TchMid Offset
(available only when
SPtRef Custom is
selected)
SPtRef Object
SPtRef Custom
Offset 0 mm
D1_OUT Offset
SPtRef Backgrnd
D1_OUT SPtRef
Figure 16. Discrete 1 Output Menu Map (Discrete 2 is identical)
3.5.1 Two-Point TEACH
The TchSpt1 and TchSPt2 options teach the desired switch points. When using the buttons, the switch points can be taught
independently. Both values must be taught when using the remote input. The same TEACH menus exist for both the
D1_OUT and D2_OUT, but the switch points are set independently.
NOTE: When in Switch mode, use
on page 17.
Navigate: MENU > Dx_OUT > Tch2Pt > TchSPt1 and navigate: MENU > Dx_OUT > Tch2Pt > TchSPt2
Remote Input: Available
Button Instructions
1. Present the target.
Action
Result
Present the target. The target must be within the sensor's range..
The target's distance measurement value
displays.
2. Access the TEACH mode and TEACH the sensor.
L-GAGE
®