background image

3.5 Discrete Output Menu (Dx_OUT)

Use this menu to view or change

Setpoints

Midpoint

Mode

Timers

Polarity

The menu options are identical for

D1_OUT and D2_OUT.

MENU D1_OUT

or

or

Go Back to Parent Menu

Select Menu Item

Press to Save Setting

Press and Hold to Go Back

to Run Mode

OffDly  0 ms
Off1Sho  0 ms
OnDly  0 ms
On1Sho  0 ms

TchSPt1 100 mm
TchSPt2 1000 mm

Tch2Pt TchSPt2

Tch2Pt TchSPt1

Mode Health

Mode Alarm

Timer On1Sho

Timer OffDly

Mode Swtch
Mode Swtch
Mode Wnd
Mode Wnd

Timer Off1Sho
Timer OnDly

AdjSPt2 1000 mm

AdjSPt1 100 mm

D1_OUT Tch2Pt

D1_OUT Mode

D1_OUT Timer

D1_OUT AdjSPt1
D1_OUT AdjSPt2

(in Swtch mode only)

WndSize 300 mm
TchMdPt 500 mm

TchMid TchMdPt

TchMid WndSize

D1_OUT TchMid

Offset 0 mm

TchMid Offset

(available only when

SPtRef Custom is 

selected)

SPtRef Object

SPtRef Custom

Offset 0 mm

D1_OUT Offset

SPtRef Backgrnd

D1_OUT SPtRef

Figure 16. Discrete 1 Output Menu Map (Discrete 2 is identical)

3.5.1 Two-Point TEACH

The TchSpt1 and TchSPt2 options teach the desired switch points. When using the buttons, the switch points can be taught

independently. Both values must be taught when using the remote input. The same TEACH menus exist for both the

D1_OUT and D2_OUT, but the switch points are set independently.

NOTE: When in Switch mode, use 

TEACH Switch Point 

on page 17.

Navigate: MENU > Dx_OUT > Tch2Pt > TchSPt1 and navigate: MENU > Dx_OUT > Tch2Pt > TchSPt2

Remote Input: Available

Button Instructions

1. Present the target.

Action

Result

Present the target. The target must be within the sensor's range..

The target's distance measurement value

displays.

2. Access the TEACH mode and TEACH the sensor.

 

 

L-GAGE

®

 LE250/550 IO-Link Laser Gauging Sensors

 

www.bannerengineering.com - Tel: 763.544.3164

13

Содержание L-GAGE LE250 IO-Link

Страница 1: ...L GAGE LE250 550 IO Link Laser Gauging Sensors Instruction Manual Original Instructions 194205 Rev A 2 December 2016 Banner Engineering Corp All rights reserved 194205...

Страница 2: ...Mode 18 3 5 8 Switch Point Reference SPtRef 20 3 5 9 Switch Point TEACH Offset 20 3 5 10 Timer 21 3 6 Input Menu INPUT 21 3 6 1 Input Type 21 3 7 Measure Menu MEASURE 22 3 7 1 Speed 22 3 8 Display Me...

Страница 3: ...20 mA analog and 1 NPN PNP discrete U 0 to 10 V analog and 1 NPN PNP discrete D 2 NPN PNP discrete NOTE Discrete NPN PNP is user configurable Output I Blank Class 2 laser C1 Class 1 Laser Laser Class...

Страница 4: ...ns Down Up Enter and Escape to program the sensor and to access sensor information Down and Up Buttons Press Down and Up to Access the Quick Menu from Run mode Navigate the menu systems Change program...

Страница 5: ...ers Do not stare at the laser Do not point the laser at a person s eye Mount open laser beam paths either above or below eye level where practical Terminate the beam emitted by the laser product at th...

Страница 6: ...ing COMPLIES WITH IEC 60825 1 2007 CLASS 1 LASER PRODUCT Output Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 Figure 4 FDA CDRH warni...

Страница 7: ...ientation in an opening Incorrect Correct Figure 7 Orientation for a turning object Incorrect Correct Figure 8 Orientation for a height difference Incorrect Correct Figure 9 Orientation for a color or...

Страница 8: ...12 30 V dc D1_Out IO Link D2_Out Input 3 1 2 4 5 Load Load Figure 11 IO Link Models Key 2 3 4 1 5 1 Brown 2 White 3 Blue 4 Black 5 Gray L GAGE LE250 550 IO Link Laser Gauging Sensors 8 www bannerengin...

Страница 9: ...Menus 3 1 Quick Menu The sensor includes a Quick Menu with easy access to view and change the discrete output switch points Access the Quick Menu by pressing Down or Up from Run mode When in the Quic...

Страница 10: ...Access discrete 2 output settings Figure 14 Sensor Menu Basic Map See Sensor Menu Full Map and the Menu sections of this manual for more information 3 3 Remote Input Use the remote input to program th...

Страница 11: ...rement value then back to Run mode 1x 3x Teaching D1D2SPt1 TchSPt1 D1 and D2 with measurement value then to TchSPt2 D1 D2 Teaching D1D2SPt2 TchSPt2 D1 D2 with measurement value then 1x 4x Teaching D1M...

Страница 12: ...ns To lock or unlock the sensor using the buttons press and hold Down and Escape simultaneously for 3 seconds Remote Input Instructions 1 Access the setup mode Action Result Double pulse the remote in...

Страница 13: ...ef Custom is selected SPtRef Object SPtRef Custom Offset 0 mm D1_OUT Offset SPtRef Backgrnd D1_OUT SPtRef Figure 16 Discrete 1 Output Menu Map Discrete 2 is identical 3 5 1 Two Point TEACH The TchSpt1...

Страница 14: ...asurement value display 3 TEACH the sensor Action Result Double pulse the remote input T T T TchSPt1 Teaching displays while the sensor is being taught TEACH Accepted The new value displays on the sec...

Страница 15: ...ensor Window Size Minimum 1 mm 10 mm Window Size Maximum 250 mm 800 mm Range 100 mm to 400 mm 100 mm to 1000 mm Default Window Size 50 mm 300 mm Navigate MENU Dx_OUT TchMid WndSize Remote Input Availa...

Страница 16: ...value displays 2 Access the TEACH midpoint mode and TEACH the sensor Action Result Navigate MENU Dx_OUT TchMid TchMdPt TchMdPt Teaching displays while the sensor is being taught TEACH Accepted The new...

Страница 17: ...the sensor s range It is required to be maintain the minimum window size between switch points This menu is not available when the sensor is in Switch Alarm or Health mode Navigate MENU Dx_OUT AdjSPt...

Страница 18: ...SPt Teaching displays while the sensor is being taught TEACH Accepted The new value displays on the second line of the display flashes and the sensor returns to Run mode TEACH Not Accepted FAIL flashe...

Страница 19: ...the switch point threshold When a target is detected farther than the switch point threshold or the signal is lost the Discrete Output is On Wnd Window Mode The Discrete Output is On while a target is...

Страница 20: ...he switching threshold relative to a taught distance using the Offset menu that appears only after selecting Custom Switch Point Reference The distance between the surface of the taught object and the...

Страница 21: ...nations of delays timers The following table shows the allowable combinations of delays timers Off Delay Off One Shot Timer On Delay On One Shot Timer Off Delay OffDly OK OK OK N A Off One Shot Timer...

Страница 22: ...e Default Setting MENU MEASURE Speed Standard Speed Fast Speed Medium Speed Slow MEASURE Speed Figure 20 Measure Menu Map 3 7 1 Speed The Speed option sets the speed at which the measurement is calcul...

Страница 23: ...e sensor Far 0 maximum range the measurement increases closer to the sensor Navigate MENU DISPLAY Zero Remote Input Not available Default Near 3 8 3 Shift Use this menu to select whether the sensor sh...

Страница 24: ...ot available Default Disabled 3 9 Information Menu INFO MENU INFO or or Go Back to Parent Menu Select Menu Item Press to Save Setting Press and Hold to Go Back to Run Mode INFO Version INFO Model Vers...

Страница 25: ...o Save Setting Press and Hold to Go Back to Run Mode RESET No RESET Yes Figure 25 Reset Menu Map 3 10 1 Factory Default Settings Discrete Output Settings LE250 LE550 Adjust Switch Point One 100 mm 100...

Страница 26: ...urements and the response speed doubles 1 Configure the first sensor as the master navigate MENU INPUT Type SyncMstr 2 Configure the second sensor as the slave navigate MENU INPUT Type SyncSlve 3 Conn...

Страница 27: ...sensor returns to step 2 and RMT TCH displays 4 Present the target Action Result Present the switch point two target D1D2Spt2 and the target s measurement value display 5 TEACH the sensor Action Resu...

Страница 28: ...ACH the sensor Action Result Six pulse the remote input T T T T T T T T T T T D1D2MdPt Teaching displays while the sensor is being taught TEACH Accepted The new value displays on the second line of th...

Страница 29: ...400 mm LE550 1 cm radius at 1 m Maximum Torque 2 N m 17 7 in lbs Indicators Power LED Indicator Solid Green Normal operation power On and laser On Flashing Green 1 Hz Power On and laser Off laser ena...

Страница 30: ...protection may be provided with external fusing or via Current Limiting Class 2 Power Supply Supply wiring leads 24 AWG shall not be spliced For additional product support go to www bannerengineering...

Страница 31: ...listed in millimeters inches unless noted otherwise Measurement Range Reference Emitted Light Clearance for M4 screws Received Light QD orients to both positions shown 0 6 mm 0 02 56 mm 2 2 35 7 mm 1...

Страница 32: ...minimum window size and completes the adjust or TEACH operation OutRnge The target is out of range too dark or the sensor is not measuring Move the target within the measurement range Power LED is fla...

Страница 33: ...srEnbl Type Teach Type SyncMstr Type SyncSlve Type Disabled Speed Standard Speed Fast Speed Medium Speed Slow Timer Off1Sho Timer OnDly AdjSPt2 1000 mm AdjSPt1 100 mm Sleep 1min Sleep Disabled Units i...

Страница 34: ...MQDEC2 530RA 9 14 m 30 ft MQDEC2 550RA 15 2 m 50 ft 9 2 Brackets All measurements are listed in millimeters unless noted otherwise SMBLEU Enclosed bracket 12 gauge stainless steel 65 68 64 A C B Hole...

Страница 35: ...OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABIL...

Отзывы: