NOTE: A No Read condition will not occur in External - Gated mode while the external trigger is active.
Command
In Command mode, the sensor will capture images when Trigger commands are received. The various trigger command modes descri-
bed above can also be set through a command channel. Refer to Communications Chapter 6 for specific commands. The commands can
come from either Serial I/O or Ethernet I/O.
Industrial Ethernet Only
When Industrial Ethernet communication channel is enabled, triggers can be received from the modes mentioned above. Triggers
through Industrial Ethernet will not be executed if selected Trigger Mode is 'Continuous Scan'. If it is desired to receive triggers only
through Industrial Ethernet channel, select the 'Industrial Ethernet Only'.